Stent-ception: implementation of soft double-J stents in the ureteric Memokath-051TM in bilateral ureteric stricture post radiotherapy for advanced prostate cancer
M. F. Mohd, M. D. M. Ashraf, M. R. Yusof, N. G. Faiz, Siti Rahmah, H. Merican, Dr Mohamed Ashraf Bin, Mohamed Daud
{"title":"Stent-ception: implementation of soft double-J stents in the ureteric Memokath-051TM in bilateral ureteric stricture post radiotherapy for advanced prostate cancer","authors":"M. F. Mohd, M. D. M. Ashraf, M. R. Yusof, N. G. Faiz, Siti Rahmah, H. Merican, Dr Mohamed Ashraf Bin, Mohamed Daud","doi":"10.17650/1726-9776-2023-19-3-100-103","DOIUrl":null,"url":null,"abstract":"Narrowing of ureter can be due to malignant or benign causes. Temporary double-J (DJ) stents, various metallic stent designs, or definitive corrective surgery can be the options management for ureteric stricture. As an alternative from DJ stents, Memokath-051TM (MMK-051TM) can be inserted in strictured ureters post radiotherapy for advanced prostate cancer patients. We present a case of an advanced prostate cancer which bilateral DJ Stents placed within MMK-051TM. A 76-year-old man with underlying hormone sensitive advanced prostate cancer completed radiotherapy. Post radiotherapy he developed bilateral ureteric strictures and bilateral DJ stents inserted. He had to underwent multiple change of stents due to blockage. Patient had MMK-051TM inserted, however complicated with blockage due to encrustation. Improvisation method done by putting the bilateral DJ stents within the MMK-051TM. Patient had no more blockage of MMK-051TM after the placement of DJ stents within it. However, patient succumbed to death a year after the last procedure. Our case report highlighted encrustation of metallic ureteric stents and a novel approach to overcome this problem. Introduction of additional DJ stents not only reduced the incidence of MMK-051TM blockage but also improved the quality of life of the patient.","PeriodicalId":216890,"journal":{"name":"Cancer Urology","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cancer Urology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17650/1726-9776-2023-19-3-100-103","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Narrowing of ureter can be due to malignant or benign causes. Temporary double-J (DJ) stents, various metallic stent designs, or definitive corrective surgery can be the options management for ureteric stricture. As an alternative from DJ stents, Memokath-051TM (MMK-051TM) can be inserted in strictured ureters post radiotherapy for advanced prostate cancer patients. We present a case of an advanced prostate cancer which bilateral DJ Stents placed within MMK-051TM. A 76-year-old man with underlying hormone sensitive advanced prostate cancer completed radiotherapy. Post radiotherapy he developed bilateral ureteric strictures and bilateral DJ stents inserted. He had to underwent multiple change of stents due to blockage. Patient had MMK-051TM inserted, however complicated with blockage due to encrustation. Improvisation method done by putting the bilateral DJ stents within the MMK-051TM. Patient had no more blockage of MMK-051TM after the placement of DJ stents within it. However, patient succumbed to death a year after the last procedure. Our case report highlighted encrustation of metallic ureteric stents and a novel approach to overcome this problem. Introduction of additional DJ stents not only reduced the incidence of MMK-051TM blockage but also improved the quality of life of the patient.
输尿管狭窄可由恶性或良性原因引起。输尿管狭窄的治疗方法有临时双J(DJ)支架、各种金属支架设计或最终矫正手术。作为 DJ 支架的替代方案,Memokath-051TM(MMK-051TM)可用于晚期前列腺癌患者放疗后输尿管狭窄的治疗。我们介绍了一例在 MMK-051TM 内放置双侧 DJ 支架的晚期前列腺癌患者。一名 76 岁的男性,患有对激素敏感的晚期前列腺癌,已完成放疗。放疗后,他出现了双侧输尿管狭窄,需要植入双侧DJ支架。 由于堵塞,他不得不多次更换支架。患者植入了 MMK-051TM,但因包壳导致堵塞。通过改进方法,将双侧 DJ 支架放入 MMK-051TM 内。在 MMK-051TM 内放置 DJ 支架后,患者的 MMK-051TM 不再堵塞。然而,患者在最后一次手术后一年去世。我们的病例报告强调了金属输尿管支架的结壳问题,以及解决这一问题的新方法。引入额外的 DJ 支架不仅降低了 MMK-051TM 阻塞的发生率,还改善了患者的生活质量。