{"title":"Facile preparation of a sensitive electrochemical sensor with good performance for determination of methionine","authors":"Peyman Mohammadzadeh Jahani, Somayeh Tajik","doi":"10.5599/jese.2038","DOIUrl":null,"url":null,"abstract":"In this work, a novel voltammetric sensor for detection of methionine was designed and prepared by using carbon paste electrode (CPE) modified with ZnO hollow quasi-spheres (ZnO hollow QSs) and 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM.PF6). The results by cyclic voltammetry (CV) showed that the prepared electrode (ZnO-BMIM.PF6/CPE) effectively increased the oxidation peak current and reduced the oxidation peak potential of methionine, and had a suitable electrocatalytic activity for oxidation of methionine. Notably, the ZnO-BMIM.PF6/CPE exhibited high detection capability towards the quantification of methionine in 0.1 M PBS (pH = 7.0) over a concentration range from 0.04 µM to 330.0 µM with a limit of detection (LOD) of 0.02 μM. More importantly, the effectiveness of the ZnO-BMIM.PF6/CPE seneor was also confirmed in real sample (urine detection with acceptable recoveries (98.0-102.7%) and RSDs values ≤ 3.3%.","PeriodicalId":14819,"journal":{"name":"Journal of Electrochemical Science and Engineering","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrochemical Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/jese.2038","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this work, a novel voltammetric sensor for detection of methionine was designed and prepared by using carbon paste electrode (CPE) modified with ZnO hollow quasi-spheres (ZnO hollow QSs) and 1-Butyl-3-methylimidazolium hexafluorophosphate (BMIM.PF6). The results by cyclic voltammetry (CV) showed that the prepared electrode (ZnO-BMIM.PF6/CPE) effectively increased the oxidation peak current and reduced the oxidation peak potential of methionine, and had a suitable electrocatalytic activity for oxidation of methionine. Notably, the ZnO-BMIM.PF6/CPE exhibited high detection capability towards the quantification of methionine in 0.1 M PBS (pH = 7.0) over a concentration range from 0.04 µM to 330.0 µM with a limit of detection (LOD) of 0.02 μM. More importantly, the effectiveness of the ZnO-BMIM.PF6/CPE seneor was also confirmed in real sample (urine detection with acceptable recoveries (98.0-102.7%) and RSDs values ≤ 3.3%.