MICROFOCUSED ULTRASOUND FOR BICHECTOMY EFFECT

Saskya Vieira Melo Aguiar, Lauscea Regina Veronezi, Márcia Vivianne Nogueira, Chrystianne Rabelo Lima Barbosa, Henrique Rodrigues Ribeiro, Juliana Lemos Maia, Gina Elayne Silva Montezuma, Marcelo Januzzi Santos
{"title":"MICROFOCUSED ULTRASOUND FOR BICHECTOMY EFFECT","authors":"Saskya Vieira Melo Aguiar, Lauscea Regina Veronezi, Márcia Vivianne Nogueira, Chrystianne Rabelo Lima Barbosa, Henrique Rodrigues Ribeiro, Juliana Lemos Maia, Gina Elayne Silva Montezuma, Marcelo Januzzi Santos","doi":"10.51249/hs.v3i06.1785","DOIUrl":null,"url":null,"abstract":"The search for aesthetic treatments is becoming increasingly common in clinics, with facial slimming being one of the most sought-after procedures. In an effort to address techniques less invasive than surgical procedures, the use of Microfocused Ultrasound (MFU) has been gaining prominence. This case report aims to evaluate the efficacy of MFU in facial slimming for a patient seeking to improve the contour of her face. Methodology: The treatment area was delimited by a line drawn from the labial commissure to the tragus, with a safety margin of 1cm on both sides. Both areas were divided into three columns (anterior, middle, and posterior) to receive the transducers. Ultrasound gel was applied to the skin before the procedure. The technology used was Reface. Initially, 4 MHz transducers with 4.5 mm depth and 0.9J power were applied to the area with 15 shots on both sides of the face, distributed as follows: six in the anterior column, six in the middle column, and three in the posterior column. Next, a 7 MHz transducer with 3.0 mm depth and 0.9J power was applied to the area with 15 shots on each side of the face, distributed similarly. The transducers were reoriented with each shot, advancing 1mm upward in both areas. These areas were chosen with the goal of slimming the middle third of the face. Results: The patient was evaluated after 60 days, and a reduction in volume on the left and right sides of the face, ranging from 1.02 to 1.79mm, was observed. The results were obtained through standardized photographs using Vectra software.","PeriodicalId":507713,"journal":{"name":"Health and Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Health and Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51249/hs.v3i06.1785","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The search for aesthetic treatments is becoming increasingly common in clinics, with facial slimming being one of the most sought-after procedures. In an effort to address techniques less invasive than surgical procedures, the use of Microfocused Ultrasound (MFU) has been gaining prominence. This case report aims to evaluate the efficacy of MFU in facial slimming for a patient seeking to improve the contour of her face. Methodology: The treatment area was delimited by a line drawn from the labial commissure to the tragus, with a safety margin of 1cm on both sides. Both areas were divided into three columns (anterior, middle, and posterior) to receive the transducers. Ultrasound gel was applied to the skin before the procedure. The technology used was Reface. Initially, 4 MHz transducers with 4.5 mm depth and 0.9J power were applied to the area with 15 shots on both sides of the face, distributed as follows: six in the anterior column, six in the middle column, and three in the posterior column. Next, a 7 MHz transducer with 3.0 mm depth and 0.9J power was applied to the area with 15 shots on each side of the face, distributed similarly. The transducers were reoriented with each shot, advancing 1mm upward in both areas. These areas were chosen with the goal of slimming the middle third of the face. Results: The patient was evaluated after 60 days, and a reduction in volume on the left and right sides of the face, ranging from 1.02 to 1.79mm, was observed. The results were obtained through standardized photographs using Vectra software.
微聚焦超声波的双切效果
在诊所里,寻求美容治疗的人越来越多,其中瘦脸是最受欢迎的治疗方法之一。为了采用比手术创伤更小的技术,微聚焦超声(MFU)的使用越来越受到重视。本病例报告旨在评估微聚焦超声波瘦脸术对一名寻求改善面部轮廓的患者的疗效。治疗方法治疗区域由唇交界处至外耳道的一条线划定,两侧各留出 1 厘米的安全余量。这两个区域被分为三列(前、中、后)以接收换能器。手术前在皮肤上涂抹超声凝胶。使用的技术是 Reface。首先,4 MHz、深度为 4.5 毫米、功率为 0.9 焦耳的换能器在脸部两侧共 15 次扫描,分布如下:前方 6 次,中间 6 次,后方 3 次。接着,用一个 7 MHz、深度 3.0 毫米、功率 0.9 焦耳的探头在面部两侧各进行 15 次扫描,分布情况类似。每次发射都会调整传感器的方向,在两个区域都向上推进 1 毫米。选择这些区域的目的是瘦脸的中间三分之一。结果60 天后对患者进行评估,观察到脸部左右两侧的体积缩小了 1.02 至 1.79 毫米。结果是通过使用 Vectra 软件拍摄的标准化照片得出的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信