Asetabulum quadrilateral bölge kırıklarına stoppa yaklaşımda kanama kontrolünde efektif ve güvenilir yeni bir teknik; obturatör arteri bağlamak

Necati Doğan
{"title":"Asetabulum quadrilateral bölge kırıklarına stoppa yaklaşımda kanama kontrolünde efektif ve güvenilir yeni bir teknik; obturatör arteri bağlamak","authors":"Necati Doğan","doi":"10.30565/medalanya.1394770","DOIUrl":null,"url":null,"abstract":"Objectives: The aim of this study is to share the solution methods obtained in the management of foci that cause bleeding in the modified stoppa approach to acetabulum quadrilateral region fractures. In addition, it is to reveal the amount of perioperative bleeding and the clinical effect of ligated arteries in patients whose surgery was performed with advanced bleeding control technique. Patients and methods: Between May 1, 2020 and June 30, 2023, perioperative bleeding data of 13 patients with acetabulum quadrilateral region fractures who were operated on with modified stoppa approach and advanced bleeding control technique were evaluated retrospectively. Age, gender, fracture mechanism, fracture side, fracture type, amount of perioperative bleeding and follow-up periods were determined. The clinical effect of ligated arteries was observed in the postoperative period. In the CT scans taken in the postoperative period, the diameters of the gluteal muscles and adductor muscles were compared to the healthy side. Results: Of the 13 patients included in the study, 5 were women and 8 were men. While the average age was 35.6 years, the average follow-up period was 15.3 months. The average number of sponges used during the modified stoppa approach and the amount of bleeding measured with an aspirator was calculated as 284.2 ml. The average area of the gluteal muscles compared to the healthy side was 0.89, while the average area of the adductor muscles was 0.89. No problems related to the ligated vessels were observed in any patient during the postoperative period and outpatient follow-up. Conclusions: Routine ligation of the obturator artery does not have any clinically observable negative effects, and with advanced bleeding control, it facilitates both the hemodynamic management of the patient in terms of anesthesia and the management of the surgical field for the surgeon.","PeriodicalId":7003,"journal":{"name":"Acta Medica Alanya","volume":"3 7","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Medica Alanya","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30565/medalanya.1394770","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: The aim of this study is to share the solution methods obtained in the management of foci that cause bleeding in the modified stoppa approach to acetabulum quadrilateral region fractures. In addition, it is to reveal the amount of perioperative bleeding and the clinical effect of ligated arteries in patients whose surgery was performed with advanced bleeding control technique. Patients and methods: Between May 1, 2020 and June 30, 2023, perioperative bleeding data of 13 patients with acetabulum quadrilateral region fractures who were operated on with modified stoppa approach and advanced bleeding control technique were evaluated retrospectively. Age, gender, fracture mechanism, fracture side, fracture type, amount of perioperative bleeding and follow-up periods were determined. The clinical effect of ligated arteries was observed in the postoperative period. In the CT scans taken in the postoperative period, the diameters of the gluteal muscles and adductor muscles were compared to the healthy side. Results: Of the 13 patients included in the study, 5 were women and 8 were men. While the average age was 35.6 years, the average follow-up period was 15.3 months. The average number of sponges used during the modified stoppa approach and the amount of bleeding measured with an aspirator was calculated as 284.2 ml. The average area of the gluteal muscles compared to the healthy side was 0.89, while the average area of the adductor muscles was 0.89. No problems related to the ligated vessels were observed in any patient during the postoperative period and outpatient follow-up. Conclusions: Routine ligation of the obturator artery does not have any clinically observable negative effects, and with advanced bleeding control, it facilitates both the hemodynamic management of the patient in terms of anesthesia and the management of the surgical field for the surgeon.
髋臼四边形骨折止血法中有效可靠的止血新技术;结扎闭孔动脉
目的:本研究旨在分享改良stoppa法治疗髋臼四边形区域骨折时处理出血病灶的解决方法。此外,本研究还将揭示采用先进出血控制技术进行手术的患者围术期出血量以及结扎动脉的临床效果。 患者和方法2020年5月1日至2023年6月30日期间,对13例采用改良stoppa入路和高级出血控制技术进行手术的髋臼四边形区域骨折患者的围手术期出血数据进行回顾性评估。确定了年龄、性别、骨折机制、骨折侧、骨折类型、围手术期出血量和随访时间。术后观察了结扎动脉的临床效果。在术后拍摄的 CT 扫描中,臀肌和内收肌的直径与健侧进行了比较。 研究结果参与研究的 13 名患者中,女性 5 人,男性 8 人。平均年龄为 35.6 岁,平均随访时间为 15.3 个月。在改良 stoppa 方法中使用的海绵的平均数量以及用吸痰器测量的出血量经计算为 284.2 毫升。与健侧相比,臀肌的平均面积为 0.89,内收肌的平均面积为 0.89。在术后和门诊随访期间,没有发现任何与结扎血管有关的问题。 结论常规结扎闭孔动脉不会产生任何临床上可观察到的负面影响,而且通过先进的出血控制,既方便了麻醉时对患者血液动力学的管理,也方便了外科医生对手术区域的管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信