Investigation of the Aging Effect of Bio-Coagulant for Oily Wastewater Treatment

M. Razali, N. Mohd Ramli, Syahirah Syazwani Mohd Tarmizi, Nasreldeen Ishag Obi
{"title":"Investigation of the Aging Effect of Bio-Coagulant for Oily Wastewater Treatment","authors":"M. Razali, N. Mohd Ramli, Syahirah Syazwani Mohd Tarmizi, Nasreldeen Ishag Obi","doi":"10.15282/jceib.v9i2.9226","DOIUrl":null,"url":null,"abstract":"The separation of oily wastewater is one of the main processes in the water treatment field. A biological approach that can replace the use of chemical coagulants hazardous to human health is an efficient solution in treating oily wastewater. However, bio- coagulants have a time limit that can affect their effectiveness in treating oily wastewater. Thus, this paper presents research for the aging effect of bio-coagulant for treating oily wastewater. In this study, G-Treat was used as the bio-coagulant, which was produced from chitosan powder, acetic acid, and deionized water. The experimental procedure started by filling 500 mL of oily wastewater into a beaker. Next, 10 wt. % of G- Treat was added into the beaker for the jar test, which was mixed for 30 min at 150 rpm, followed by 2 h settling time. Then, the mixture was separated using filter paper. The analysis of oily wastewater characteristics was conducted using five types of analyses, which are pH, chemical oxygen demand (COD), biological oxygen demand (BOD), total sus- pended solids (TSS), and oil and grease (O&G) under the parameters of days (0–7 days), weeks (0–6 weeks), and months (0–3 months). From the result, the best performance of G-Treat was achieved at the optimum parameters during week 2, with 33.16%, 65.75%, 35.73%, 28.58%, and 0% removal of pH, COD, BOD, TSS, and O&G, respectively. In conclusion, the studied bio-coagulant demonstrated higher removal of pH, COD, BOD, TSS, and O&G at optimum parameters, and eventually, the level of effectiveness will drop.","PeriodicalId":235976,"journal":{"name":"Journal of Chemical Engineering and Industrial Biotechnology","volume":" 53","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chemical Engineering and Industrial Biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15282/jceib.v9i2.9226","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The separation of oily wastewater is one of the main processes in the water treatment field. A biological approach that can replace the use of chemical coagulants hazardous to human health is an efficient solution in treating oily wastewater. However, bio- coagulants have a time limit that can affect their effectiveness in treating oily wastewater. Thus, this paper presents research for the aging effect of bio-coagulant for treating oily wastewater. In this study, G-Treat was used as the bio-coagulant, which was produced from chitosan powder, acetic acid, and deionized water. The experimental procedure started by filling 500 mL of oily wastewater into a beaker. Next, 10 wt. % of G- Treat was added into the beaker for the jar test, which was mixed for 30 min at 150 rpm, followed by 2 h settling time. Then, the mixture was separated using filter paper. The analysis of oily wastewater characteristics was conducted using five types of analyses, which are pH, chemical oxygen demand (COD), biological oxygen demand (BOD), total sus- pended solids (TSS), and oil and grease (O&G) under the parameters of days (0–7 days), weeks (0–6 weeks), and months (0–3 months). From the result, the best performance of G-Treat was achieved at the optimum parameters during week 2, with 33.16%, 65.75%, 35.73%, 28.58%, and 0% removal of pH, COD, BOD, TSS, and O&G, respectively. In conclusion, the studied bio-coagulant demonstrated higher removal of pH, COD, BOD, TSS, and O&G at optimum parameters, and eventually, the level of effectiveness will drop.
含油废水处理中生物凝固剂的老化效应研究
含油废水分离是水处理领域的主要工艺之一。生物方法可以取代对人类健康有害的化学混凝剂,是处理含油废水的有效解决方案。然而,生物混凝剂有时间限制,会影响其处理含油废水的效果。因此,本文对生物混凝剂处理含油废水的老化效果进行了研究。本研究使用 G-Treat 作为生物混凝剂,它由壳聚糖粉末、醋酸和去离子水制成。实验过程首先是在烧杯中注入 500 毫升含油废水。然后,在烧杯中加入 10 wt. % 的 G- Treat 进行罐式试验,在 150 rpm 的转速下搅拌 30 分钟,然后沉淀 2 小时。然后,用滤纸分离混合物。含油废水特性分析采用了五种分析方法,分别是 pH 值、化学需氧量(COD)、生物需氧量(BOD)、总悬浮固体(TSS)和油脂(O&G),参数分别为天(0-7 天)、周(0-6 周)和月(0-3 个月)。结果表明,在第 2 周的最佳参数下,G-Treat 的性能最佳,对 pH、COD、BOD、TSS 和 O&G 的去除率分别为 33.16%、65.75%、35.73%、28.58% 和 0%。总之,所研究的生物凝结剂在最佳参数下对 pH、COD、BOD、TSS 和 O&G 的去除率较高,但最终效果会下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信