{"title":"Self-healing capacity of GCLs under simulated field conditions","authors":"Jinchun Chai , Xiaoxiao Zhu , Jixiang Nie , Takenori Hino","doi":"10.1016/j.geotexmem.2023.12.006","DOIUrl":null,"url":null,"abstract":"<div><p>The self-healing capacities of a GCL<span><span> with natural bentonite (NB) as core (NB-GCL) and a </span>GCL<span><span> with a polymerized bentonite (PB) as core (PB-GCL) were investigated under simulated field conditions, i.e. geomembrane-GCL-a clayey subsoil layer composite liner system with a damage hole on the </span>geomembrane<span><span> and the GCL. The clayey subsoils tested had </span>initial water contents<span> of 22.2% and 26.8%. The liquids used were deionized (DI) water and 0.3 M NaCl solution. The test results indicate that for both the PB-GCL and NB-GCL only hydrated on the subsoils for 1–3 months, a damage hole of 15 mm in diameter was almost not self-healed. For cases of applying a constant liquid head on the top of the geomembrane of 100 mm, the sizes of damage holes were self-healed in term of diameter is about half of the values reported in the literature for tests with plenty liquid supply to the damaged GCLs. Further, for the conditions tested and for the cases self-healed, DI water leaked into the subsoil was less than about 60 g, and 0.3 M NaCl solution leaked was less than 150 g.</span></span></span></span></p></div>","PeriodicalId":55096,"journal":{"name":"Geotextiles and Geomembranes","volume":null,"pages":null},"PeriodicalIF":4.7000,"publicationDate":"2024-01-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geotextiles and Geomembranes","FirstCategoryId":"89","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0266114423001115","RegionNum":1,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, GEOLOGICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The self-healing capacities of a GCL with natural bentonite (NB) as core (NB-GCL) and a GCL with a polymerized bentonite (PB) as core (PB-GCL) were investigated under simulated field conditions, i.e. geomembrane-GCL-a clayey subsoil layer composite liner system with a damage hole on the geomembrane and the GCL. The clayey subsoils tested had initial water contents of 22.2% and 26.8%. The liquids used were deionized (DI) water and 0.3 M NaCl solution. The test results indicate that for both the PB-GCL and NB-GCL only hydrated on the subsoils for 1–3 months, a damage hole of 15 mm in diameter was almost not self-healed. For cases of applying a constant liquid head on the top of the geomembrane of 100 mm, the sizes of damage holes were self-healed in term of diameter is about half of the values reported in the literature for tests with plenty liquid supply to the damaged GCLs. Further, for the conditions tested and for the cases self-healed, DI water leaked into the subsoil was less than about 60 g, and 0.3 M NaCl solution leaked was less than 150 g.
期刊介绍:
The range of products and their applications has expanded rapidly over the last decade with geotextiles and geomembranes being specified world wide. This rapid growth is paralleled by a virtual explosion of technology. Current reference books and even manufacturers' sponsored publications tend to date very quickly and the need for a vehicle to bring together and discuss the growing body of technology now available has become evident.
Geotextiles and Geomembranes fills this need and provides a forum for the dissemination of information amongst research workers, designers, users and manufacturers. By providing a growing fund of information the journal increases general awareness, prompts further research and assists in the establishment of international codes and regulations.