Morphology of the knee after guided growth using tension-band devices: a retrospective multicenter study of 222 limbs and 285 implants.

IF 2.5 2区 医学 Q1 ORTHOPEDICS
Emma Hvidberg, Carina Antfang, Georg Gosheger, Bjoern Vogt, Ahmed Abood, Alexander Møller-San Pedro, Adrien Frommer, Veronika Weyer-Elberich, Maria Kirstine Møller-Madsen, Robert Roedl, Bjarne Møller-Madsen, Jan Duedal Rölfing
{"title":"Morphology of the knee after guided growth using tension-band devices: a retrospective multicenter study of 222 limbs and 285 implants.","authors":"Emma Hvidberg, Carina Antfang, Georg Gosheger, Bjoern Vogt, Ahmed Abood, Alexander Møller-San Pedro, Adrien Frommer, Veronika Weyer-Elberich, Maria Kirstine Møller-Madsen, Robert Roedl, Bjarne Møller-Madsen, Jan Duedal Rölfing","doi":"10.2340/17453674.2023.34902","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and purpose: </strong>Temporary hemiepiphysiodesis by tension-band devices is commonly applied to correct angular limb deformities in children. We aimed to evaluate knee joint morphology after guided growth using these devices.</p><p><strong>Patients and methods: </strong>In a retrospective multicenter study we analyzed standardized anteroposterior long-leg radiographs of 222 limbs (285 implants) of patients treated by temporary hemiepiphysiodesis with either eight-Plates or FlexTacks for coronal angular deformities of the knee joint between 2013 and 2019. Femoral floor angle (FFA), femoral notch-intercondylar distance (FNID), and tibial roof angle (TRA) were measured pre- and postoperatively to assess the central knee joint morphology. Statistical exploratory analyses were performed using linear mixed models, t-tests, Wilcoxon signed-rank test, and Mann-Whitney U test.</p><p><strong>Results: </strong>217 FlexTacks (femur 106, tibia 111) in 104 children and 68 eight-Plates (femur 61, tibia 7) in 35 children were identified. Median time period under growth guidance was 11 months (range 4-42). No statistically significant change in the FFA was detected (eight-Plate: P = 0.2; FlexTack: P = 0.3). A statistically significant difference of the FNID was found in the eight-Plate group (P = 0.02), but not in the FlexTack group (P = 0.3). While TRA increased in both groups, a statistical significance was observed only in the FlexTack group (P < 0.01).</p><p><strong>Conclusion: </strong>We found minor but clinically irrelevant changes in knee morphology after the treatment.</p>","PeriodicalId":6916,"journal":{"name":"Acta Orthopaedica","volume":"94 ","pages":"609-615"},"PeriodicalIF":2.5000,"publicationDate":"2023-12-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10755675/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Orthopaedica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2340/17453674.2023.34902","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background and purpose: Temporary hemiepiphysiodesis by tension-band devices is commonly applied to correct angular limb deformities in children. We aimed to evaluate knee joint morphology after guided growth using these devices.

Patients and methods: In a retrospective multicenter study we analyzed standardized anteroposterior long-leg radiographs of 222 limbs (285 implants) of patients treated by temporary hemiepiphysiodesis with either eight-Plates or FlexTacks for coronal angular deformities of the knee joint between 2013 and 2019. Femoral floor angle (FFA), femoral notch-intercondylar distance (FNID), and tibial roof angle (TRA) were measured pre- and postoperatively to assess the central knee joint morphology. Statistical exploratory analyses were performed using linear mixed models, t-tests, Wilcoxon signed-rank test, and Mann-Whitney U test.

Results: 217 FlexTacks (femur 106, tibia 111) in 104 children and 68 eight-Plates (femur 61, tibia 7) in 35 children were identified. Median time period under growth guidance was 11 months (range 4-42). No statistically significant change in the FFA was detected (eight-Plate: P = 0.2; FlexTack: P = 0.3). A statistically significant difference of the FNID was found in the eight-Plate group (P = 0.02), but not in the FlexTack group (P = 0.3). While TRA increased in both groups, a statistical significance was observed only in the FlexTack group (P < 0.01).

Conclusion: We found minor but clinically irrelevant changes in knee morphology after the treatment.

使用张力带装置引导膝关节生长后的形态:一项对 222 个肢体和 285 个植入物进行的多中心回顾性研究。
背景和目的:通过张力带装置进行临时半腓骨牵引通常用于矫正儿童肢体成角畸形。我们旨在评估使用这些装置引导生长后的膝关节形态:在一项回顾性多中心研究中,我们分析了2013年至2019年期间使用8-Plates或FlexTacks进行膝关节冠状成角畸形临时半骨骺成形术治疗的患者的222个肢体(285个植入物)的标准化前胸长腿X光片。术前和术后测量了股骨底角(FFA)、股骨切迹-髁间距离(FNID)和胫骨顶角(TRA),以评估膝关节中央形态。采用线性混合模型、t检验、Wilcoxon符号秩检验和Mann-Whitney U检验进行统计探索性分析。结果:104名患儿的217枚FlexTacks(股骨106枚,胫骨111枚)和35名患儿的68枚8-Plates(股骨61枚,胫骨7枚)得到确认。接受生长指导的中位时间为 11 个月(4-42 个月)。未发现 FFA 有统计学意义的变化(八板:P = 0.2;FlexTack:P = 0.3)。八平板组的 FNID 有明显的统计学差异(P = 0.02),而 FlexTack 组则没有(P = 0.3)。虽然两组的 TRA 都有所增加,但只有 FlexTack 组的 TRA 有统计学意义(P < 0.01):我们发现治疗后膝关节形态发生了轻微但与临床无关的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Orthopaedica
Acta Orthopaedica 医学-整形外科
CiteScore
6.40
自引率
8.10%
发文量
105
审稿时长
4-8 weeks
期刊介绍: Acta Orthopaedica (previously Acta Orthopaedica Scandinavica) presents original articles of basic research interest, as well as clinical studies in the field of orthopedics and related sub disciplines. Ever since the journal was founded in 1930, by a group of Scandinavian orthopedic surgeons, the journal has been published for an international audience. Acta Orthopaedica is owned by the Nordic Orthopaedic Federation and is the official publication of this federation.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信