Non-invasive and Sensitive Fluorescence Detection of Phenylpyruvic Acid via a Guanidinomethyl-modified Calixarene

IF 3.4 Q2 CHEMISTRY, ANALYTICAL
Huan-Yu Wang, Zong-Ying Hu, Han-Wen Tian, Dr. Xin-Yue Hu, Dr. Yu-Chen Pan, Dr. Dong-Sheng Guo
{"title":"Non-invasive and Sensitive Fluorescence Detection of Phenylpyruvic Acid via a Guanidinomethyl-modified Calixarene","authors":"Huan-Yu Wang,&nbsp;Zong-Ying Hu,&nbsp;Han-Wen Tian,&nbsp;Dr. Xin-Yue Hu,&nbsp;Dr. Yu-Chen Pan,&nbsp;Dr. Dong-Sheng Guo","doi":"10.1002/anse.202300082","DOIUrl":null,"url":null,"abstract":"<p>Detection of phenylpyruvic acid (PPA) is important for the diagnosis of phenylketonuria (PKU). In this study, we designed a guanidinomethyl-modified calix[5]arene that can strongly and selectively bind with PPA. Via indicator displacement assay, we set up a calibration line for accurately determining PPA concentration down to the μM range in artificial urine based on the linear relationship between the fluorescence intensity and PPA concentration. This work provides a low-cost, easy-to-operate, rapid, and sensitive method for PPA detection, and may offer an alternative for PKU diagnosis in clinical study.</p>","PeriodicalId":72192,"journal":{"name":"Analysis & sensing","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analysis & sensing","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/anse.202300082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Detection of phenylpyruvic acid (PPA) is important for the diagnosis of phenylketonuria (PKU). In this study, we designed a guanidinomethyl-modified calix[5]arene that can strongly and selectively bind with PPA. Via indicator displacement assay, we set up a calibration line for accurately determining PPA concentration down to the μM range in artificial urine based on the linear relationship between the fluorescence intensity and PPA concentration. This work provides a low-cost, easy-to-operate, rapid, and sensitive method for PPA detection, and may offer an alternative for PKU diagnosis in clinical study.

Abstract Image

通过胍基甲基修饰的钙烯烃对苯丙酮酸进行非侵入式灵敏荧光检测
检测苯丙酮酸(PPA)对于诊断苯丙酮尿症(PKU)非常重要。在这项研究中,我们设计了一种胍基甲基修饰的钙[5]炔,它能与 PPA 强选择性结合。通过指示剂置换测定,我们建立了一条校准线,可根据荧光强度与 PPA 浓度之间的线性关系,准确测定人工尿液中 PPA 的浓度,最低可达 μM。这项工作提供了一种低成本、易操作、快速而灵敏的 PPA 检测方法,可为临床研究中的 PKU 诊断提供一种替代方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信