Method Development and Validation for the Simultaneous Estimation of Pregabalin, Methylcobalamin and Nortriptyline in Sustained Release Tablet Dosage Form Using UV-Spectrophotometry

Sonali Sonulkar, Khush R. Jain, Fariah F. Rizwani, Rakesh Somani, Rupesh Pingale
{"title":"Method Development and Validation for the Simultaneous Estimation of Pregabalin, Methylcobalamin and Nortriptyline in Sustained Release Tablet Dosage Form Using UV-Spectrophotometry","authors":"Sonali Sonulkar, Khush R. Jain, Fariah F. Rizwani, Rakesh Somani, Rupesh Pingale","doi":"10.9734/ajocs/2023/v13i6276","DOIUrl":null,"url":null,"abstract":"To method develop and validate simple, linear, rapid, cost effective, precise, accurate and economical for the simultaneous estimation of Pregabalin, Methylcobalamin and Nortriptyline in sustained release tablet dosage form using UV-Spectrophotometry. The drug obeyed the Beer’s law and showed good correlation of concentration with absorption which reflect in linearity. The UV- Spectroscopic method was developed for estimation of Pregabalin, Methylcobalamin and Nortriptyline in sustained release tablet dosage form and also validated as per ICH guidelines. The method is based on measurement of absorbance at three wavelengths 219 nm, 222 nm, and 239 nm in Ethanol and distilled water. Linearity graph of Pregabalin, Methylcobalamin and Nortriptyline were found to be linear in the concentration ranges of 30-150 µg/ml, 0.6-3.0 µg/ml and 2-10 µg/ml. The correlation coefficient (R2) values at three wavelengths 219 nm, 222 nm, and 239 nm for Pregabalin are 0.9996, 0.9929, and 0.9996; for Methylcobalamin (R2) values are 0.9998, 0.9991, and 0.9997; for Nortriptyline (R2) values are 1.0, 0.9992 and 0.9997. The low % RSD values indicate method to be accurate and precise. The % recoveries of Pregabalin, Methylcobalamin and Nortriptyline were in the range of (99.30%-1-1.61%), (98.89%-100.02%) and (99.69%-100.23%) which was within standard acceptance limits.  All other validation parameters were performed by following respective ICH guidelines.","PeriodicalId":8505,"journal":{"name":"Asian Journal of Chemical Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Chemical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/ajocs/2023/v13i6276","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

To method develop and validate simple, linear, rapid, cost effective, precise, accurate and economical for the simultaneous estimation of Pregabalin, Methylcobalamin and Nortriptyline in sustained release tablet dosage form using UV-Spectrophotometry. The drug obeyed the Beer’s law and showed good correlation of concentration with absorption which reflect in linearity. The UV- Spectroscopic method was developed for estimation of Pregabalin, Methylcobalamin and Nortriptyline in sustained release tablet dosage form and also validated as per ICH guidelines. The method is based on measurement of absorbance at three wavelengths 219 nm, 222 nm, and 239 nm in Ethanol and distilled water. Linearity graph of Pregabalin, Methylcobalamin and Nortriptyline were found to be linear in the concentration ranges of 30-150 µg/ml, 0.6-3.0 µg/ml and 2-10 µg/ml. The correlation coefficient (R2) values at three wavelengths 219 nm, 222 nm, and 239 nm for Pregabalin are 0.9996, 0.9929, and 0.9996; for Methylcobalamin (R2) values are 0.9998, 0.9991, and 0.9997; for Nortriptyline (R2) values are 1.0, 0.9992 and 0.9997. The low % RSD values indicate method to be accurate and precise. The % recoveries of Pregabalin, Methylcobalamin and Nortriptyline were in the range of (99.30%-1-1.61%), (98.89%-100.02%) and (99.69%-100.23%) which was within standard acceptance limits.  All other validation parameters were performed by following respective ICH guidelines.
使用紫外分光光度法同时测定缓释片剂型中普瑞巴林、甲钴胺和去甲替林的方法开发与验证
目的:采用紫外分光光度法同时测定缓释片剂中的普瑞巴林、甲钴胺和去甲替林,该方法简单、线性、快速、经济、精确、准确、经济。药物符合比尔定律,浓度与吸收呈良好的线性相关。该紫外分光光度法适用于缓释片剂中普瑞巴林、甲钴胺和去甲替林的测定,并根据 ICH 指南进行了验证。该方法基于在乙醇和蒸馏水中 219 纳米、222 纳米和 239 纳米三个波长处测量吸光度。普瑞巴林、甲钴胺和去甲替林在 30-150 微克/毫升、0.6-3.0 微克/毫升和 2-10 微克/毫升的浓度范围内呈线性关系。普瑞巴林在 219 nm、222 nm 和 239 nm 三个波长下的相关系数 (R2) 值分别为 0.9996、0.9929 和 0.9996;甲钴胺 (R2) 值分别为 0.9998、0.9991 和 0.9997;去甲替林 (R2) 值分别为 1.0、0.9992 和 0.9997。较低的 RSD 值表明该方法是准确和精确的。普瑞巴林、甲钴胺和去甲替林的回收率分别为(99.30%-1-1.61%)、(98.89%-100.02%)和(99.69%-100.23%),均在标准接受范围内。 所有其他验证参数均按照相应的 ICH 指南进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信