Pedro Henrique de Aguiar Moreira, Patrick Pereira Garcia, Myrella do Nascimento Correia, Narla Dos Reis Bacelar Chaves, Camilo Pulido, Michel Wendlinger Cantanhede Ferreira, Alessandra Reis, Fabiana Suelen Figuerêdo de Siqueira, Alessandro D Loguercio, Andres Felipe Millan Cardenas
{"title":"Long-term Evaluation of Dentin Bonding Properties of the Photoinitiator System Contained in Universal Adhesives Used in Fiber-Post Luting Procedures.","authors":"Pedro Henrique de Aguiar Moreira, Patrick Pereira Garcia, Myrella do Nascimento Correia, Narla Dos Reis Bacelar Chaves, Camilo Pulido, Michel Wendlinger Cantanhede Ferreira, Alessandra Reis, Fabiana Suelen Figuerêdo de Siqueira, Alessandro D Loguercio, Andres Felipe Millan Cardenas","doi":"10.3290/j.jad.b4786551","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the long-term push-out bond strength (PBS) and nanoleakage (NL) of universal adhesives with different photo-initiator systems in the root canals of teeth in which fiber posts were luted.</p><p><strong>Materials and methods: </strong>One-hundred twenty endodontically treated human premolars were randomly divided into 12 groups based on the following factors: adhesives (Scotchbond Universal [SBU], Ambar Universal [AMB], and Ambar Universal APS [AMB-APS]); adhesive strategy (etch-and-rinse and self-etch), and time of testing (immediately vs after 2 years). The posts were cemented, sectioned into slices, tested for PBS at 0.5 mm/min, and examined for NL using scanning electron microscopy immediately thereafter or after 2 years of water storage. Data were evaluated using a four-way ANOVA (root thirds vs time vs universal adhesive vs adhesive strategies) and Tukey's test (α = 5%).</p><p><strong>Results: </strong>For both evaluation times, AMB-APS demonstrated no significant difference in the PBS or NL when different radicular thirds were compared (p > 0.05). However, for SBU and AMB, the cervical third demonstrated higher PBS and lower NL than those of the apical third at both time points (p < 0.0001). AMB-APS exhibited higher PBS and lower NL in the apical third in comparison with SBU and AMB (p < 0.0001). SBU and AMB displayed a significant decrease in the PBS and increased NL after 2 years (p < 0.0001), whereas AMB-APS demonstrated no significant signs of degradation even after 2 years of water storage (p > 0.05).</p><p><strong>Conclusion: </strong>Independent of the root third evaluated, the universal adhesive containing APS photo-initiator system demonstrated bonding stability at the adhesive interface between the root canal and fiber posts, even after 2 years of water storage.</p>","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"25 1","pages":"257-266"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of adhesive dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.jad.b4786551","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study evaluated the long-term push-out bond strength (PBS) and nanoleakage (NL) of universal adhesives with different photo-initiator systems in the root canals of teeth in which fiber posts were luted.
Materials and methods: One-hundred twenty endodontically treated human premolars were randomly divided into 12 groups based on the following factors: adhesives (Scotchbond Universal [SBU], Ambar Universal [AMB], and Ambar Universal APS [AMB-APS]); adhesive strategy (etch-and-rinse and self-etch), and time of testing (immediately vs after 2 years). The posts were cemented, sectioned into slices, tested for PBS at 0.5 mm/min, and examined for NL using scanning electron microscopy immediately thereafter or after 2 years of water storage. Data were evaluated using a four-way ANOVA (root thirds vs time vs universal adhesive vs adhesive strategies) and Tukey's test (α = 5%).
Results: For both evaluation times, AMB-APS demonstrated no significant difference in the PBS or NL when different radicular thirds were compared (p > 0.05). However, for SBU and AMB, the cervical third demonstrated higher PBS and lower NL than those of the apical third at both time points (p < 0.0001). AMB-APS exhibited higher PBS and lower NL in the apical third in comparison with SBU and AMB (p < 0.0001). SBU and AMB displayed a significant decrease in the PBS and increased NL after 2 years (p < 0.0001), whereas AMB-APS demonstrated no significant signs of degradation even after 2 years of water storage (p > 0.05).
Conclusion: Independent of the root third evaluated, the universal adhesive containing APS photo-initiator system demonstrated bonding stability at the adhesive interface between the root canal and fiber posts, even after 2 years of water storage.