Effects of staining and bleaching procedures on the optical and surface properties of CAD-CAM materials.

IF 0.9 4区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
American journal of dentistry Pub Date : 2023-12-01
Özge G Yenİdünya, Nİhan Gönülol, Tuğba Mİsİllİ, Lena Bal, İbrahİm İnanc
{"title":"Effects of staining and bleaching procedures on the optical and surface properties of CAD-CAM materials.","authors":"Özge G Yenİdünya, Nİhan Gönülol, Tuğba Mİsİllİ, Lena Bal, İbrahİm İnanc","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine the effects of coffee staining and bleaching applications on the optical properties of CAD-CAM blocks, and to provide a three-dimensional visualization of surface changes with atomic force microscope (AFM).</p><p><strong>Methods: </strong>80 samples were prepared from four different CAD-CAM blocks: [Cerec (CR), Shofu (SH), Cerasmart (CRS), Lava Ultimate (LU)], and a microhybrid composite resin [Filtek Z250 (Z250)]. After staining, the samples were divided into two subgroups according to bleaching methods: 16% carbamide peroxide (HB), and 40% hydrogen peroxide (OB). Color measurements were performed at baseline (t₀), after staining (t₁), and after bleaching (t₂) to obtain translucency parameters (TP₀₀), color change (ΔE₀₀), and whiteness index (WID) values. Surface roughness analysis (Ra) was performed with AFM after coffee staining and bleaching procedures (at t₁ and t₂). Data were analyzed with Generalized Linear Model, and Bonferroni correction (P< 0.05).</p><p><strong>Results: </strong>TP₀₀ values increased only in the CRS group after the bleaching application, and the effect of method was again observed only in CRS. While bleaching increased WID values of all groups except CRS, no difference was found between bleaching methods. Regardless of evaluation time, the roughest group is Z250, and the only difference between bleaching methods was observed in the CR group. In conclusion, the effects of staining and bleaching applications on the optical and surface properties of CAD-CAM blocks are material-dependent.</p><p><strong>Clinical significance: </strong>Effective bleaching of discolored CAD-CAM materials was achieved regardless of the bleaching method used, and without any significant adverse effect on the surface properties of the materials.</p>","PeriodicalId":7538,"journal":{"name":"American journal of dentistry","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of dentistry","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To examine the effects of coffee staining and bleaching applications on the optical properties of CAD-CAM blocks, and to provide a three-dimensional visualization of surface changes with atomic force microscope (AFM).

Methods: 80 samples were prepared from four different CAD-CAM blocks: [Cerec (CR), Shofu (SH), Cerasmart (CRS), Lava Ultimate (LU)], and a microhybrid composite resin [Filtek Z250 (Z250)]. After staining, the samples were divided into two subgroups according to bleaching methods: 16% carbamide peroxide (HB), and 40% hydrogen peroxide (OB). Color measurements were performed at baseline (t₀), after staining (t₁), and after bleaching (t₂) to obtain translucency parameters (TP₀₀), color change (ΔE₀₀), and whiteness index (WID) values. Surface roughness analysis (Ra) was performed with AFM after coffee staining and bleaching procedures (at t₁ and t₂). Data were analyzed with Generalized Linear Model, and Bonferroni correction (P< 0.05).

Results: TP₀₀ values increased only in the CRS group after the bleaching application, and the effect of method was again observed only in CRS. While bleaching increased WID values of all groups except CRS, no difference was found between bleaching methods. Regardless of evaluation time, the roughest group is Z250, and the only difference between bleaching methods was observed in the CR group. In conclusion, the effects of staining and bleaching applications on the optical and surface properties of CAD-CAM blocks are material-dependent.

Clinical significance: Effective bleaching of discolored CAD-CAM materials was achieved regardless of the bleaching method used, and without any significant adverse effect on the surface properties of the materials.

染色和漂白程序对 CAD-CAM 材料的光学和表面特性的影响。
目的:研究咖啡染色和漂白应用对 CAD-CAM 块体光学特性的影响,并利用原子力显微镜(AFM)提供表面变化的三维可视化:方法:从四种不同的 CAD-CAM 块体[Cerec (CR)、Shofu (SH)、Cerasmart (CRS)、Lava Ultimate (LU)]和微混合复合树脂[Filtek Z250 (Z250)]中制备 80 个样品。染色后,根据漂白方法将样品分为两个亚组:16% 过氧化碳酰胺(HB)和 40% 过氧化氢(OB)。分别在基线(t₀)、染色后(t₁)和漂白后(t₂)进行颜色测量,以获得半透明参数(TP₀₀)、颜色变化(ΔE₀₀)和白度指数(WID)值。在咖啡染色和漂白过程后(t₁ 和 t₂),用原子力显微镜进行表面粗糙度(Ra)分析。数据采用广义线性模型进行分析,并进行 Bonferroni 校正(P< 0.05):结果:漂白后,只有 CRS 组的 TP₀₀值升高,而且只有 CRS 组的 TP₀₀值升高。虽然除 CRS 外,漂白会增加所有组别的 WID 值,但漂白方法之间并无差异。无论评估时间长短,最粗糙的组别都是 Z250,而漂白方法之间的唯一差异是在 CR 组中观察到的。总之,染色和漂白应用对 CAD-CAM 块体的光学和表面特性的影响与材料有关:临床意义:无论使用哪种漂白方法,都能对变色的 CAD-CAM 材料进行有效漂白,而且不会对材料的表面特性产生明显的不利影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
American journal of dentistry
American journal of dentistry 医学-牙科与口腔外科
CiteScore
2.40
自引率
7.10%
发文量
57
审稿时长
1 months
期刊介绍: The American Journal of Dentistry, published by Mosher & Linder, Inc., provides peer-reviewed scientific articles with clinical significance for the general dental practitioner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信