Accuracy of formula-based volume and image segmentation-based volume in calculation of preoperative cystic jaw lesions’ volume

IF 1.6 3区 医学 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Yasmein Maher El-beblawy, Ahmed Mohamed Bakry, Maha Eshaq Amer Mohamed
{"title":"Accuracy of formula-based volume and image segmentation-based volume in calculation of preoperative cystic jaw lesions’ volume","authors":"Yasmein Maher El-beblawy, Ahmed Mohamed Bakry, Maha Eshaq Amer Mohamed","doi":"10.1007/s11282-023-00731-5","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Objective</h3><p>The aim of this study was to assess the accuracy of formula-based volume measurements and the 3D volume analysis with different software packages in the calculation of preoperative cystic jaw lesions’ volume. The secondary aim was to assess the reliability and the accuracy of 3 imaging software programs for measuring the cystic jaw lesions' volume in CBCT images.</p><h3 data-test=\"abstract-sub-heading\">Materials and methods</h3><p>This study consisted of two parts: an in vitro part using 2 dry human mandibles that were used to create simulated osteolytic lesions to assess the accuracy of the volumetric analysis and formula-based volume. As a gold standard, the volume of each bone defect was determined by taking an impression using rapid soft silicone (Vinylight) and then quantifying the volume of the replica. Afterward, each tooth socket was scanned using a high-resolution CBCT. A retrospective part using archived CBCT radiographs that were taken from the database of the outpatient clinic of the oral and maxillofacial radiology department, Faculty of Dentistry, Minia University to assess the reliability of the 3 software packages. The volumetric data set was exported for volume quantification using the 3 software packages (MIMICS-OnDemand and InVesalius software). Also, the three greatest orthogonal diameters of the lesions were calculated, and the volume was assessed using the ellipsoid formula. Dunn’s test was used for pair-wise comparisons when Friedman’s test was significant. The inter-examiner agreement was assessed using Cronbach’s alpha reliability coefficient and intra-class correlation coefficient.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>Regarding the results of the retrospective part, there was a statistically significant difference between volumetric measurements by equation and different software (<i>P</i> value &lt; 0.001, Effect size = 0.513). The inter-observer reliability of the measurements of the cystic lesions using the different software packages was very good. The highest inter-examiner agreement for volume measurement was found with InVesalius (Cronbach’s alpha = 0.992). On the other hand, there was a statistically significant difference between dry mandible volumetric measurements and Gold Standard. All software showed statistically significantly lower dry mandible volumetric measurements than the gold standard.</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>Computer-aided assessment of cystic lesion volume using InVesalius, OnDemand, and MIMICS is a readily available, easy to use, non-invasive option. It confers an advantage over formula-based volume as it gives the exact morphology of the lesion so that potential problems can be detected before surgery. Volume analysis with InVesalius software was accurate in determining the volume of simulated periapical defects in a human cadaver mandible as compared to true volume. InVesalius software proved that open-source software can be robust yet user-friendly with the advantage of minimal cost to use.</p>","PeriodicalId":56103,"journal":{"name":"Oral Radiology","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2023-12-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11282-023-00731-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

The aim of this study was to assess the accuracy of formula-based volume measurements and the 3D volume analysis with different software packages in the calculation of preoperative cystic jaw lesions’ volume. The secondary aim was to assess the reliability and the accuracy of 3 imaging software programs for measuring the cystic jaw lesions' volume in CBCT images.

Materials and methods

This study consisted of two parts: an in vitro part using 2 dry human mandibles that were used to create simulated osteolytic lesions to assess the accuracy of the volumetric analysis and formula-based volume. As a gold standard, the volume of each bone defect was determined by taking an impression using rapid soft silicone (Vinylight) and then quantifying the volume of the replica. Afterward, each tooth socket was scanned using a high-resolution CBCT. A retrospective part using archived CBCT radiographs that were taken from the database of the outpatient clinic of the oral and maxillofacial radiology department, Faculty of Dentistry, Minia University to assess the reliability of the 3 software packages. The volumetric data set was exported for volume quantification using the 3 software packages (MIMICS-OnDemand and InVesalius software). Also, the three greatest orthogonal diameters of the lesions were calculated, and the volume was assessed using the ellipsoid formula. Dunn’s test was used for pair-wise comparisons when Friedman’s test was significant. The inter-examiner agreement was assessed using Cronbach’s alpha reliability coefficient and intra-class correlation coefficient.

Results

Regarding the results of the retrospective part, there was a statistically significant difference between volumetric measurements by equation and different software (P value < 0.001, Effect size = 0.513). The inter-observer reliability of the measurements of the cystic lesions using the different software packages was very good. The highest inter-examiner agreement for volume measurement was found with InVesalius (Cronbach’s alpha = 0.992). On the other hand, there was a statistically significant difference between dry mandible volumetric measurements and Gold Standard. All software showed statistically significantly lower dry mandible volumetric measurements than the gold standard.

Conclusion

Computer-aided assessment of cystic lesion volume using InVesalius, OnDemand, and MIMICS is a readily available, easy to use, non-invasive option. It confers an advantage over formula-based volume as it gives the exact morphology of the lesion so that potential problems can be detected before surgery. Volume analysis with InVesalius software was accurate in determining the volume of simulated periapical defects in a human cadaver mandible as compared to true volume. InVesalius software proved that open-source software can be robust yet user-friendly with the advantage of minimal cost to use.

Abstract Image

基于公式的体积和基于图像分割的体积在计算术前颌骨囊性病变体积时的准确性
本研究的目的是评估在计算术前颌骨囊性病变体积时,基于公式的体积测量和不同软件包的三维体积分析的准确性。材料和方法本研究由两部分组成:体外部分使用 2 个干燥的人类下颌骨来创建模拟溶骨病灶,以评估体积分析和基于公式的体积的准确性。作为金标准,每个骨缺损的体积是通过使用快速软硅胶(Vinylight)取印模确定的,然后量化复制品的体积。之后,使用高分辨率 CBCT 扫描每个牙槽骨。使用从米尼亚大学牙科学院口腔颌面放射科门诊数据库中提取的存档 CBCT X 光片进行回顾性分析,以评估 3 套软件的可靠性。体积数据集通过 3 款软件包(MIMICS-OnDemand 和 InVesalius 软件)导出进行体积量化。此外,还计算了病变的三个最大正交直径,并使用椭圆体公式评估了体积。如果弗里德曼检验结果显著,则采用邓恩检验进行配对比较。用 Cronbach's alpha 信度系数和类内相关系数评估了检查者之间的一致性。结果回顾性部分的结果显示,用方程和不同软件测量的体积有显著的统计学差异(P 值 < 0.001,效应大小 = 0.513)。使用不同软件对囊性病变进行测量的观察者间可靠性非常好。在体积测量方面,InVesalius 的检查者间一致性最高(Cronbach's alpha = 0.992)。另一方面,干下颌骨体积测量结果与黄金标准之间存在显著的统计学差异。结论使用 InVesalius、OnDemand 和 MIMICS 对囊性病变体积进行计算机辅助评估是一种现成、易用、无创的选择。它比基于公式的体积评估更具优势,因为它能提供病变的确切形态,从而在手术前发现潜在的问题。与真实体积相比,使用 InVesalius 软件进行的体积分析能准确确定人体尸体下颌骨模拟根尖周缺损的体积。InVesalius 软件证明了开放源码软件的强大功能和用户友好性,以及使用成本最低的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Oral Radiology
Oral Radiology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.20
自引率
13.60%
发文量
87
审稿时长
>12 weeks
期刊介绍: As the official English-language journal of the Japanese Society for Oral and Maxillofacial Radiology and the Asian Academy of Oral and Maxillofacial Radiology, Oral Radiology is intended to be a forum for international collaboration in head and neck diagnostic imaging and all related fields. Oral Radiology features cutting-edge research papers, review articles, case reports, and technical notes from both the clinical and experimental fields. As membership in the Society is not a prerequisite, contributions are welcome from researchers and clinicians worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信