How Much Air is Needed to Ventilate the Gym? – Case Study

IF 1 Q4 ENGINEERING, CIVIL
P. Kapalo, F. Domniţa, C. Bacotiu, H. Albu, M. Chvatal
{"title":"How Much Air is Needed to Ventilate the Gym? – Case Study","authors":"P. Kapalo, F. Domniţa, C. Bacotiu, H. Albu, M. Chvatal","doi":"10.2478/jaes-2023-0029","DOIUrl":null,"url":null,"abstract":"Abstract In order to design a ventilation system based on the volumetric airflow rate, which will ensure satisfactory indoor air quality and, at the same time, do not oversize the system, it is necessary to know the quantities of pollutants emissions. The concentration of produced pollutants allows the calculation of the required fresh air volumetric flow rate. Two previous published studies are analysed in this article, whose results complement each other. From the calculated values, the graphical dependence between the required fresh air volumetric flow rate and the level of physical activity was developed. It was noticed that, according to the Slovak and Romanian legislation, for the studied gym, there is insufficient air ventilation. At an allowed maximum CO2 concentration level of 1,000 ppm, the required fresh air volumetric flow rate, according to legislative requirements, will ensure a percentage of only 75.59% to 23.25% of the necessary rate (depending of the type of physical activity). For a lower allowed maximum CO2 concentration level, the ensured fresh air volumetric flow rate will be even smaller. The aim of the article is to contribute to the development of healthy environments in fitness centres and gyms and to optimize the design requirements for their ventilation systems.","PeriodicalId":44808,"journal":{"name":"Journal of Applied Engineering Sciences","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jaes-2023-0029","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract In order to design a ventilation system based on the volumetric airflow rate, which will ensure satisfactory indoor air quality and, at the same time, do not oversize the system, it is necessary to know the quantities of pollutants emissions. The concentration of produced pollutants allows the calculation of the required fresh air volumetric flow rate. Two previous published studies are analysed in this article, whose results complement each other. From the calculated values, the graphical dependence between the required fresh air volumetric flow rate and the level of physical activity was developed. It was noticed that, according to the Slovak and Romanian legislation, for the studied gym, there is insufficient air ventilation. At an allowed maximum CO2 concentration level of 1,000 ppm, the required fresh air volumetric flow rate, according to legislative requirements, will ensure a percentage of only 75.59% to 23.25% of the necessary rate (depending of the type of physical activity). For a lower allowed maximum CO2 concentration level, the ensured fresh air volumetric flow rate will be even smaller. The aim of the article is to contribute to the development of healthy environments in fitness centres and gyms and to optimize the design requirements for their ventilation systems.
健身房通风需要多少空气? - 案例研究
为了设计基于容积式风量的通风系统,既能保证满意的室内空气质量,又不会使系统过大,有必要了解污染物的排放量。产生的污染物的浓度允许计算所需的新鲜空气体积流量。本文分析了之前发表的两项研究,其结果相辅相成。根据计算值,开发了所需的新鲜空气体积流量与身体活动水平之间的图形依赖关系。有人注意到,根据斯洛伐克和罗马尼亚的立法,所研究的体育馆通风不足。在允许的最大二氧化碳浓度水平为1000ppm时,根据立法要求,所需的新鲜空气体积流量将确保仅占必要流量的75.59%至23.25%(取决于身体活动的类型)。对于较低的允许最大二氧化碳浓度水平,确保的新鲜空气体积流量将更小。本文的目的是促进健身中心和健身房健康环境的发展,并优化其通风系统的设计要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
9.10%
发文量
18
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信