Reliability of kinematic waveforms during gait analysis with total hip arthroplasty patients

Ben Langley , Henrike Greaves , Chris Whelton , Richard Page , Mary Cramp , Stewart C. Morrison , Paola Dey , Tim Board
{"title":"Reliability of kinematic waveforms during gait analysis with total hip arthroplasty patients","authors":"Ben Langley ,&nbsp;Henrike Greaves ,&nbsp;Chris Whelton ,&nbsp;Richard Page ,&nbsp;Mary Cramp ,&nbsp;Stewart C. Morrison ,&nbsp;Paola Dey ,&nbsp;Tim Board","doi":"10.1016/j.jjoisr.2023.11.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Purpose</h3><p>The aim of the study was to determine the test-retest reliability of lower limb kinematic waveforms derived from 3D gait analysis (3DGA) in patients following total hip arthroplasty (THA).</p></div><div><h3>Methods</h3><p>Eight (7 ​M:1F; age: 70 ​± ​7 years; height: 1.68 ​± ​0.11 ​m; mass: 85 ​± ​20 ​kg) adults with a unilateral THA attended test and retest sessions. 3DGA was undertaken with participants walking at a self-selected pace along a 7 ​m walkway within each session. The standard error or the measurement (SEM) was calculated for hip, knee and ankle joint angles in all three planes, over the walking gait cycle.</p></div><div><h3>Results</h3><p>The SEM ranged from 2.9 to 4.1°, 2.7–3.7° and 1.9–3.9°, in the sagittal, frontal and traverse planes at the hip. At the knee the SEM ranged from 1.6 to 4.2°, 1.0–1.9° and 1.3–2.9° in the sagittal, frontal and transverse planes, respectively. While the SEM ranged from 0.7 to 2.0°, 1.2–2.3° and 2.9–4.0° in the sagittal, frontal and transverse planes at the ankle.</p></div><div><h3>Conclusions</h3><p>The findings demonstrate that 3DGA provides a reliable means of quantifying lower limb kinematics over the walking gait cycle in patients following THA, with all SEM values below the 5° threshold previously suggested to identify clinically meaningful differences. The SEM values reported may aid in the interpretation of changes in lower limb kinematics in patients following THA.</p></div>","PeriodicalId":100795,"journal":{"name":"Journal of Joint Surgery and Research","volume":"2 1","pages":"Pages 1-6"},"PeriodicalIF":0.0000,"publicationDate":"2023-12-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2949705123000397/pdfft?md5=926b9ef5d567638b8f62039493ab1ca1&pid=1-s2.0-S2949705123000397-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Joint Surgery and Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2949705123000397","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose

The aim of the study was to determine the test-retest reliability of lower limb kinematic waveforms derived from 3D gait analysis (3DGA) in patients following total hip arthroplasty (THA).

Methods

Eight (7 ​M:1F; age: 70 ​± ​7 years; height: 1.68 ​± ​0.11 ​m; mass: 85 ​± ​20 ​kg) adults with a unilateral THA attended test and retest sessions. 3DGA was undertaken with participants walking at a self-selected pace along a 7 ​m walkway within each session. The standard error or the measurement (SEM) was calculated for hip, knee and ankle joint angles in all three planes, over the walking gait cycle.

Results

The SEM ranged from 2.9 to 4.1°, 2.7–3.7° and 1.9–3.9°, in the sagittal, frontal and traverse planes at the hip. At the knee the SEM ranged from 1.6 to 4.2°, 1.0–1.9° and 1.3–2.9° in the sagittal, frontal and transverse planes, respectively. While the SEM ranged from 0.7 to 2.0°, 1.2–2.3° and 2.9–4.0° in the sagittal, frontal and transverse planes at the ankle.

Conclusions

The findings demonstrate that 3DGA provides a reliable means of quantifying lower limb kinematics over the walking gait cycle in patients following THA, with all SEM values below the 5° threshold previously suggested to identify clinically meaningful differences. The SEM values reported may aid in the interpretation of changes in lower limb kinematics in patients following THA.

全髋关节置换术患者步态分析中运动学波形的可靠性
目的研究全髋关节置换术(THA)患者下肢三维步态分析(3DGA)所得下肢运动波形的重测可靠性。方法:7 M:1F;年龄:70±7岁;高度:1.68±0.11 m;体重:85±20 kg)单侧THA患者参加了检查和复查。在3DGA中,参与者以自己选择的速度沿着7米长的人行道行走。计算了三个平面的髋关节、膝关节和踝关节角度在步行周期内的测量标准误差(SEM)。结果髋关节矢状面、正位面和横位面扫描电镜(SEM)范围为2.9 ~ 4.1°、2.7 ~ 3.7°和1.9 ~ 3.9°。膝关节矢状面、正位面和横面扫描电镜分别为1.6 ~ 4.2°、1.0 ~ 1.9°和1.3 ~ 2.9°。踝关节矢状面、正位面和横位的扫描电镜范围为0.7 ~ 2.0°、1.2 ~ 2.3°和2.9 ~ 4.0°。研究结果表明,3DGA提供了一种可靠的方法来量化THA后患者在步行步态周期中的下肢运动学,所有扫描电镜值都低于先前建议的5°阈值,以识别临床有意义的差异。报道的扫描电镜值可能有助于解释THA后患者下肢运动学的变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信