{"title":"[Pericardial puncture under linear array real time ultrasound guidance].","authors":"J L Deng","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This article reported 14 cases of pericardial puncture under ultrasound guidance with total success and without any complications. This technique is safer and more accurate than conventional method. The localization of puncture site and the technique were introduced. A common linear array transducer coupled with a self-made end-entering guide is the instrument needed which is simple and effective.</p>","PeriodicalId":39377,"journal":{"name":"Zhonghua fang she xue za zhi Chinese journal of radiology","volume":"23 6","pages":"340-1"},"PeriodicalIF":0.0000,"publicationDate":"1989-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua fang she xue za zhi Chinese journal of radiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
This article reported 14 cases of pericardial puncture under ultrasound guidance with total success and without any complications. This technique is safer and more accurate than conventional method. The localization of puncture site and the technique were introduced. A common linear array transducer coupled with a self-made end-entering guide is the instrument needed which is simple and effective.