A Prospective Study of Immediately Loaded Single Implant-Retained Mandibular Overdentures: Long-Term Results with 15-Year Follow-up.

Glen Liddelow, Veronica Wilshaw, Patrick Henry
{"title":"A Prospective Study of Immediately Loaded Single Implant-Retained Mandibular Overdentures: Long-Term Results with 15-Year Follow-up.","authors":"Glen Liddelow, Veronica Wilshaw, Patrick Henry","doi":"10.11607/ijp.8404","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To investigate the long-term predictability of simplifying mandibular overdenture treatment using single-stage surgery and immediate prosthetic loading of a single implant to provide a more affordable treatment option.</p><p><strong>Materials and methods: </strong>A total of 29 patients with a mean age of 68 years with problematic mandibular dentures were treated. A single implant (Brånemark System Mklll TiUnite, Nobel Biocare) was placed into the mandibular midline for primary stability. A ball attachment was placed, and the retentive cap was incorporated into the existing denture. The patients were recalled at 3 and 12 months and at 3, 5, 10, and 15 years. Clinical assessments, radiographs, and resonance frequency analysis were recorded. All complications, failures, maintenance, and reasons for failure to follow-up were noted. Visual analog scale (VAS) questionnaires were used to record patient satisfaction (ANOVA; P < .05).</p><p><strong>Results: </strong>One implant did not achieve sufficient primary stability to be immediately loaded and was treated with a two-stage delayed loading protocol. Of the 28 patients receiving immediately loaded implants, 14 patients were available for follow-up at 15 years. Implant survival remained at 100% throughout the study. Patient satisfaction was high, with a significant increase in all comfort and functional parameters (P values ranged from < .001 to .07) throughout the 15-year period.</p><p><strong>Conclusions: </strong>These 15-year results indicate that immediate loading of a single oxidized surface implant used to retain a mucosa-borne overdenture is a safe, reliable, and cost-effective treatment with high levels of patient satisfaction long term.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"145-152"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.8404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To investigate the long-term predictability of simplifying mandibular overdenture treatment using single-stage surgery and immediate prosthetic loading of a single implant to provide a more affordable treatment option.

Materials and methods: A total of 29 patients with a mean age of 68 years with problematic mandibular dentures were treated. A single implant (Brånemark System Mklll TiUnite, Nobel Biocare) was placed into the mandibular midline for primary stability. A ball attachment was placed, and the retentive cap was incorporated into the existing denture. The patients were recalled at 3 and 12 months and at 3, 5, 10, and 15 years. Clinical assessments, radiographs, and resonance frequency analysis were recorded. All complications, failures, maintenance, and reasons for failure to follow-up were noted. Visual analog scale (VAS) questionnaires were used to record patient satisfaction (ANOVA; P < .05).

Results: One implant did not achieve sufficient primary stability to be immediately loaded and was treated with a two-stage delayed loading protocol. Of the 28 patients receiving immediately loaded implants, 14 patients were available for follow-up at 15 years. Implant survival remained at 100% throughout the study. Patient satisfaction was high, with a significant increase in all comfort and functional parameters (P values ranged from < .001 to .07) throughout the 15-year period.

Conclusions: These 15-year results indicate that immediate loading of a single oxidized surface implant used to retain a mucosa-borne overdenture is a safe, reliable, and cost-effective treatment with high levels of patient satisfaction long term.

即刻加载单种植体下颌覆盖义齿的前瞻性研究:15年随访的长期结果。
目的:本前瞻性研究的目的是研究简化下颌覆盖义齿治疗的长期可预测性,采用单期手术和立即加载单种植体的义齿,以提供更实惠的治疗选择。材料与方法:对29例平均年龄68岁的下颌义齿问题患者进行治疗。将单个种植体(bramatnemark TiUnite Mk ll)置入下颌中线,获得初步稳定。放置一个球附件,并将固位帽并入现有的义齿。患者在3个月和12个月以及3岁、5岁、10岁和15岁时被召回。记录临床评估、x线片和共振频率分析。记录所有并发症、故障、维护和未随访的原因。使用视觉模拟量表问卷记录患者满意度(方差分析结果:一颗种植体未达到足够的初级稳定性,无法立即加载,因此采用两阶段延迟加载方案进行治疗。)在28名接受即刻植入物的患者中,14名患者在15年随访。在整个研究过程中,种植体的存活率保持在100%。结论:这些15年的研究结果表明,立即使用单一氧化表面种植体来固定粘膜覆盖义齿是一种安全、可靠、经济有效的治疗方法,患者的长期满意度很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信