Efficacy and safety of the Arctic Sun device for hypoxic-ischemic encephalopathy in adult patients following cardiopulmonary resuscitation: A systematic review and meta-analysis

IF 2.3 4区 医学 Q3 CLINICAL NEUROLOGY
MandipSingh Bhatia, SaurabhC Sharda, RohitR Jakhotia, Ashish Behera, Atul Saroch, AshokKumar Pannu, HMohan Kumar
{"title":"Efficacy and safety of the Arctic Sun device for hypoxic-ischemic encephalopathy in adult patients following cardiopulmonary resuscitation: A systematic review and meta-analysis","authors":"MandipSingh Bhatia, SaurabhC Sharda, RohitR Jakhotia, Ashish Behera, Atul Saroch, AshokKumar Pannu, HMohan Kumar","doi":"10.4103/bc.bc_18_23","DOIUrl":null,"url":null,"abstract":"AIM: The principal objective of this study was to carry out a comprehensive and thorough analysis to compare the safety and effectiveness of the Arctic Sun, a servo-controlled surface cooling device, with conventional cooling techniques for providing therapeutic hypothermia in adult patients who had experienced hypoxic-ischemic brain injury following cardiopulmonary resuscitation. METHODS: In order to achieve our goal, we conducted an extensive search of multiple databases including PubMed, Embase, Cochrane, and ClinicalTrials.gov up to the date of July 30, 2021. We only included studies that compared the safety and efficacy of the Arctic Sun surface cooling equipment with standard cooling approaches such as cooling blankets, ice packs, and intravenous cold saline for treating comatose adult patients who had recovered after experiencing cardiac arrest. We evaluated various outcomes, including all-cause mortality, good neurological outcome at 1 month, and the occurrence of adverse effects such as infections, shock, and bleeding. We employed a random-effects meta-analysis to estimate the odds ratio (OR) with 95% confidence intervals (CIs) for dichotomous outcomes. RESULTS: One hundred and fourteen records were identified through our search; however, only three studies met our eligibility criteria, resulting in overall 187 patients incorporated in the meta-analysis. The findings indicated no significant difference in mortality rates among the Arctic Sun device and conventional cooling techniques (OR: 0.64; 95% CI: 0.34–1.19; P = 0.16; I2 = 0%). In addition, we found no significant difference in occurrence of good neurological outcomes (OR: 1.74; 95% CI: 0.94–3.25; P = 0.08; I2 = 0%) between the two cooling methods. However, the application of the Arctic Sun device was associated with increased incidence of infections compared to standard cooling methods (OR: 2.46; 95% CI: 1.18–5.11; P = 0.02; I2 = 0%). While no significant difference occurred in the incidence of shock (OR: 0.29; 95% CI: 0.07–1.18; P = 0.08; I2 = 40%), the use of the Arctic Sun device was linked to significantly fewer bleeding complications compared to standard cooling methods (OR: 0.11; 95% CI: 0.02–0.79; P = 0.03; I2 = 0%). CONCLUSIONS: After analyzing the results of our meta-analysis, we concluded that the use of the Arctic Sun device for targeted temperature management following cardiopulmonary resuscitation did not result in significant differences in mortality rates or improve neurological outcomes when compared to standard cooling techniques.","PeriodicalId":9288,"journal":{"name":"Brain Circulation","volume":"38 1","pages":"0"},"PeriodicalIF":2.3000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brain Circulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/bc.bc_18_23","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

AIM: The principal objective of this study was to carry out a comprehensive and thorough analysis to compare the safety and effectiveness of the Arctic Sun, a servo-controlled surface cooling device, with conventional cooling techniques for providing therapeutic hypothermia in adult patients who had experienced hypoxic-ischemic brain injury following cardiopulmonary resuscitation. METHODS: In order to achieve our goal, we conducted an extensive search of multiple databases including PubMed, Embase, Cochrane, and ClinicalTrials.gov up to the date of July 30, 2021. We only included studies that compared the safety and efficacy of the Arctic Sun surface cooling equipment with standard cooling approaches such as cooling blankets, ice packs, and intravenous cold saline for treating comatose adult patients who had recovered after experiencing cardiac arrest. We evaluated various outcomes, including all-cause mortality, good neurological outcome at 1 month, and the occurrence of adverse effects such as infections, shock, and bleeding. We employed a random-effects meta-analysis to estimate the odds ratio (OR) with 95% confidence intervals (CIs) for dichotomous outcomes. RESULTS: One hundred and fourteen records were identified through our search; however, only three studies met our eligibility criteria, resulting in overall 187 patients incorporated in the meta-analysis. The findings indicated no significant difference in mortality rates among the Arctic Sun device and conventional cooling techniques (OR: 0.64; 95% CI: 0.34–1.19; P = 0.16; I2 = 0%). In addition, we found no significant difference in occurrence of good neurological outcomes (OR: 1.74; 95% CI: 0.94–3.25; P = 0.08; I2 = 0%) between the two cooling methods. However, the application of the Arctic Sun device was associated with increased incidence of infections compared to standard cooling methods (OR: 2.46; 95% CI: 1.18–5.11; P = 0.02; I2 = 0%). While no significant difference occurred in the incidence of shock (OR: 0.29; 95% CI: 0.07–1.18; P = 0.08; I2 = 40%), the use of the Arctic Sun device was linked to significantly fewer bleeding complications compared to standard cooling methods (OR: 0.11; 95% CI: 0.02–0.79; P = 0.03; I2 = 0%). CONCLUSIONS: After analyzing the results of our meta-analysis, we concluded that the use of the Arctic Sun device for targeted temperature management following cardiopulmonary resuscitation did not result in significant differences in mortality rates or improve neurological outcomes when compared to standard cooling techniques.
北极太阳装置治疗成人心肺复苏后缺氧缺血性脑病的疗效和安全性:一项系统综述和荟萃分析
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Brain Circulation
Brain Circulation Multiple-
自引率
5.30%
发文量
31
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信