Reliability of Software Prediction of Post Orthodontic Treatment Changes

Swatika Sankrit, Ankur Gupta, Dhruv Krishana Tiwari, Anil K. Chandana, Preeti Bhattacharya, Ravi Bhandari, Shivani Singh
{"title":"Reliability of Software Prediction of Post Orthodontic Treatment Changes","authors":"Swatika Sankrit, Ankur Gupta, Dhruv Krishana Tiwari, Anil K. Chandana, Preeti Bhattacharya, Ravi Bhandari, Shivani Singh","doi":"10.1177/03015742231188212","DOIUrl":null,"url":null,"abstract":"Aim The aim of this study was to assess the accuracy of Dolphin VTO prediction in patients requiring extraction treatment by comparing the VTO-predicted values and post-treatment values. Method Digital pre and post-treatment lateral cephalograms of 52 patients having Class I bimaxillary protrusion were taken and transferred in Dolphin Imaging software for analysis and VTO prediction. A composite analysis was made containing 17 dental and soft tissue parameters (Holdaway, Mc Namara, Rakosi, Steiners, and Tweed analysis). Results A comparison between post-treatment and VTO-predicted values showed that software was able to predict soft tissue changes accurately in regions such as nose, inferior sulcus depth, and chin region ( p > .05). In dental changes, software was able to predict the inclination of upper incisors to Sn and palatal plane correctly ( p > .05). Parameters for other areas such as upper and lower lip, position of upper and lower incisor show significant difference in their VTO and post-treatment values ( p < .05) showing inaccuracy of the software. Conclusion The VTO prediction of dental and soft tissue changes was significantly different from the post-treatment values for parameters such as superior sulcus depth, lower lip to h line, subnasal to h line, upper lip thickness, lip strain, nasolabial angle, interincisal angle, Ui-NA, Li-NB, and IMPA. For nasal prominence, inferior sulcus depth, chin thickness, UI-SN, and UI-PP, there was no significant difference seen. Since, for most of the parameters, a significant difference was found between the post-treatment and the predicted values, so it was inferred that the software-based VTO prediction could not be fully relied for any treatment planning.","PeriodicalId":31847,"journal":{"name":"Journal of Indian Orthodontic Society","volume":"26 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Orthodontic Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/03015742231188212","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim The aim of this study was to assess the accuracy of Dolphin VTO prediction in patients requiring extraction treatment by comparing the VTO-predicted values and post-treatment values. Method Digital pre and post-treatment lateral cephalograms of 52 patients having Class I bimaxillary protrusion were taken and transferred in Dolphin Imaging software for analysis and VTO prediction. A composite analysis was made containing 17 dental and soft tissue parameters (Holdaway, Mc Namara, Rakosi, Steiners, and Tweed analysis). Results A comparison between post-treatment and VTO-predicted values showed that software was able to predict soft tissue changes accurately in regions such as nose, inferior sulcus depth, and chin region ( p > .05). In dental changes, software was able to predict the inclination of upper incisors to Sn and palatal plane correctly ( p > .05). Parameters for other areas such as upper and lower lip, position of upper and lower incisor show significant difference in their VTO and post-treatment values ( p < .05) showing inaccuracy of the software. Conclusion The VTO prediction of dental and soft tissue changes was significantly different from the post-treatment values for parameters such as superior sulcus depth, lower lip to h line, subnasal to h line, upper lip thickness, lip strain, nasolabial angle, interincisal angle, Ui-NA, Li-NB, and IMPA. For nasal prominence, inferior sulcus depth, chin thickness, UI-SN, and UI-PP, there was no significant difference seen. Since, for most of the parameters, a significant difference was found between the post-treatment and the predicted values, so it was inferred that the software-based VTO prediction could not be fully relied for any treatment planning.
正畸术后治疗变化软件预测的可靠性
目的本研究旨在通过比较VTO预测值和治疗后值来评估Dolphin预测拔牙患者VTO的准确性。方法对52例I类双颌前突患者进行治疗前后的数字侧位脑电图,并在Dolphin Imaging软件中进行分析和VTO预测。进行了包含17个牙齿和软组织参数的复合分析(Holdaway, Mc Namara, Rakosi, Steiners和Tweed分析)。结果术后与vto预测值的比较表明,软件能够准确预测鼻部、下沟深度、颏部等区域的软组织变化(p >. 05)。在牙齿变化中,软件能够正确预测上切牙对Sn和腭平面的倾斜度(p >. 05)。上下唇、上下切牙位置等其他部位参数的VTO及处理后值差异有统计学意义(p <.05)显示软件不准确。结论VTO预测的上沟深度、下唇至h线、鼻下至h线、上唇厚度、唇应变、鼻唇角、牙内角、Ui-NA、Li-NB、IMPA等参数与治疗后差异有统计学意义。在鼻突、下沟深度、下巴厚度、UI-SN、UI-PP方面,两组间无显著差异。由于大多数参数处理后与预测值存在显著差异,因此可以推断,对于任何治疗方案,基于软件的VTO预测都不能完全依赖。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
46
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信