None Dr Anamika Abraham, None Dr. Angleena Y Daniel, None Dr. Achsah Ann Thomas
{"title":"Revitalizing Worn-Out Overdenture Attachments in One-Piece Implant Cases using Silicone Matrix System: A Case Report","authors":"None Dr Anamika Abraham, None Dr. Angleena Y Daniel, None Dr. Achsah Ann Thomas","doi":"10.21276/ujds.2023.9.3.15","DOIUrl":null,"url":null,"abstract":"The case report discusses the use of a silicone matrix system for salvaging worn-out overdenture attachments in one-piece implant cases. It highlights the effectiveness of this technique and presents a detailed case study. One-piece or single-piece implant systems, where the intraosseous and abutment portions with the stud attachments consist of one unit, do not allow changing the worn-out abutment individually if required, thus ruling out any further use of implant and abutment once the attachment component faces extensive irreversible wearing. The ‘Retention. Sil’ – an additional curing elastomeric material in salvaging worn-out attachments of one-piece implants, emphasizes the revitalization process and effective use as an attachment for implant-retained overdenture, thereby extending the clinical use of one-piece implants and avoiding extensive invasive procedures in geriatric patients.","PeriodicalId":100856,"journal":{"name":"King Saud University Journal of Dental Sciences","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"King Saud University Journal of Dental Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21276/ujds.2023.9.3.15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The case report discusses the use of a silicone matrix system for salvaging worn-out overdenture attachments in one-piece implant cases. It highlights the effectiveness of this technique and presents a detailed case study. One-piece or single-piece implant systems, where the intraosseous and abutment portions with the stud attachments consist of one unit, do not allow changing the worn-out abutment individually if required, thus ruling out any further use of implant and abutment once the attachment component faces extensive irreversible wearing. The ‘Retention. Sil’ – an additional curing elastomeric material in salvaging worn-out attachments of one-piece implants, emphasizes the revitalization process and effective use as an attachment for implant-retained overdenture, thereby extending the clinical use of one-piece implants and avoiding extensive invasive procedures in geriatric patients.