Examining the Intra-Rater Reliability of Transcranial Magnetic Stimulation (TMS)-Induced Motor Evoked Potentials (MEPs) Within and Between Sessions: A Step Towards Ensuring Accuracy of Observed MEP Changes in Repeated Measures Studies conducted by Newly Trained TMS Operators

Q4 Medicine
Abubakar Tijjani Salihu, Keith D Hill, Maryam Zoghi, Shapour Jaberzadeh
{"title":"Examining the Intra-Rater Reliability of Transcranial Magnetic Stimulation (TMS)-Induced Motor Evoked Potentials (MEPs) Within and Between Sessions: A Step Towards Ensuring Accuracy of Observed MEP Changes in Repeated Measures Studies conducted by Newly Trained TMS Operators","authors":"Abubakar Tijjani Salihu, Keith D Hill, Maryam Zoghi, Shapour Jaberzadeh","doi":"10.5812/mejrh-138723","DOIUrl":null,"url":null,"abstract":"Background: An essential factor in the validity of motor evoked potential (MEP)s recorded by transcranial magnetic stimulation (TMS) over multiple times is their test-retest reliability which to a large extent depends on the accuracy and competence of the assessor (intra-rater reliability). However, intra-rater reliability is infrequently reported in TMS studies suggesting that this is rarely done. Objectives: This study was conducted to determine the intra-rater within and between-session reliability of a newly trained TMS assessor prior to a main TMS study and report on the methodology used to encourage similar practice. Methods: Fourteen (10 males, 4 females; mean age: 32 ± 5.8 years) participants took part in the study. Motor evoked potentials were elicited from a relaxed, right first dorsal interosseous (FDI) muscle three times (T1, T2 and T3) across two testing sessions at least 48 hours apart. During the first session, MEPs were recorded twice (T1 and T2) within an interval of 20 minutes to determine the within (intra) session reliability of the assessor. During the second session, a single measurement was carried out (T3) which was compared to T1 to determine the inter-session reliability. Results: Repeated measure analysis of variance (ANOVA) did not reveal significant difference in the amplitude of the MEPs obtained across the three time periods (P = 0.196) demonstrating agreement in the MEPs and hence the reliability of the assessor. Additionally, the intraclass correlation coefficient (ICC) between T1 and T2; and T1 and T3 were 0.952 (P < 0.001) and 0.833 (P = 0.001) respectively further indicating the within and between sessions reliability of the assessor. Conclusions: The agreement between the three measured MEPs amplitude and the significant ICC demonstrates the reliability of the assessor in this study to use TMS for research. We suggest that the intra-rater reliability of new TMS operators should be established using the methodology in this report prior to main TMS studies.","PeriodicalId":36354,"journal":{"name":"Middle East Journal of Rehabilitation and Health","volume":"81 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Middle East Journal of Rehabilitation and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5812/mejrh-138723","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: An essential factor in the validity of motor evoked potential (MEP)s recorded by transcranial magnetic stimulation (TMS) over multiple times is their test-retest reliability which to a large extent depends on the accuracy and competence of the assessor (intra-rater reliability). However, intra-rater reliability is infrequently reported in TMS studies suggesting that this is rarely done. Objectives: This study was conducted to determine the intra-rater within and between-session reliability of a newly trained TMS assessor prior to a main TMS study and report on the methodology used to encourage similar practice. Methods: Fourteen (10 males, 4 females; mean age: 32 ± 5.8 years) participants took part in the study. Motor evoked potentials were elicited from a relaxed, right first dorsal interosseous (FDI) muscle three times (T1, T2 and T3) across two testing sessions at least 48 hours apart. During the first session, MEPs were recorded twice (T1 and T2) within an interval of 20 minutes to determine the within (intra) session reliability of the assessor. During the second session, a single measurement was carried out (T3) which was compared to T1 to determine the inter-session reliability. Results: Repeated measure analysis of variance (ANOVA) did not reveal significant difference in the amplitude of the MEPs obtained across the three time periods (P = 0.196) demonstrating agreement in the MEPs and hence the reliability of the assessor. Additionally, the intraclass correlation coefficient (ICC) between T1 and T2; and T1 and T3 were 0.952 (P < 0.001) and 0.833 (P = 0.001) respectively further indicating the within and between sessions reliability of the assessor. Conclusions: The agreement between the three measured MEPs amplitude and the significant ICC demonstrates the reliability of the assessor in this study to use TMS for research. We suggest that the intra-rater reliability of new TMS operators should be established using the methodology in this report prior to main TMS studies.
检查经颅磁刺激(TMS)诱发的运动诱发电位(MEPs)在会话内和会话之间的可靠性:确保新训练的TMS操作员进行的重复测量研究中观察到的MEP变化的准确性的一步
背景:经颅磁刺激(TMS)多次记录的运动诱发电位(MEP)效度的一个重要因素是其重测信度,而重测信度在很大程度上取决于评估者的准确性和能力(评分者内信度)。然而,在经颅磁刺激研究中很少有报道表明这种情况很少发生。目的:本研究旨在确定新培训的经颅磁刺激评估者在主要经颅磁刺激研究之前的内部评估者和会话之间的可靠性,并报告用于鼓励类似实践的方法。方法:14例(男10例,女4例;参与者平均年龄:32±5.8岁。运动诱发电位从放松的右第一背骨间肌(FDI)激发三次(T1, T2和T3),两次测试间隔至少48小时。在第一次会议期间,在20分钟的间隔内记录两次mep (T1和T2),以确定评估者在会议内(会议内)的可靠性。在第二阶段,进行单一测量(T3),将其与T1进行比较,以确定会话间可靠性。结果:重复测量方差分析(ANOVA)没有显示在三个时间段内获得的mep振幅有显著差异(P = 0.196),证明了mep的一致性,因此评估器的可靠性。此外,T1和T2之间的类内相关系数(ICC);T1和T3分别为0.952 (P <0.001)和0.833 (P = 0.001),进一步表明评估者在会议内和会议间的信度。结论:三个测量的MEPs振幅与显著的ICC之间的一致性证明了本研究中评估者使用TMS进行研究的可靠性。我们建议,在主要的经颅磁刺激研究之前,应该使用本报告中的方法建立新的经颅磁刺激操作员的内部可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
37
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信