Detection of synthetic lipid‐lowering adulterants in herbal products using high‐performance thin‐layer chromatography

IF 1.3 Q4 CHEMISTRY, ANALYTICAL
Hardi Joshi, Payal Bahliwala, Jigna Vadalia, Udaykumar Vegad
{"title":"Detection of synthetic lipid‐lowering adulterants in herbal products using high‐performance thin‐layer chromatography","authors":"Hardi Joshi, Payal Bahliwala, Jigna Vadalia, Udaykumar Vegad","doi":"10.1002/sscp.202300165","DOIUrl":null,"url":null,"abstract":"Abstract Adulterating herbal medicine with undeclared synthetic drugs is a worldwide problem that seriously threatens human health. To detect such illicit and not labeled synthetic hypolipidemic substances in herbal medicines, an analytical method to simultaneously identify and quantify atorvastatin (ATV) calcium, simvastatin (SIM), gemfibrozil (GEM), fenofibrate (FEN) belonging to two different classes of drugs (statins and fibrates) was developed based on high‐performance thin‐layer chromatography. The method consisted of Silica Gel G60 F 254 precoated aluminum plate as stationary phase and toluene: ethyl acetate: formic acid (7:3:0.3, v/v/v) as optimized mobile phase. The densitometric evaluation wavelength was optimized at 254 nm. The Rf values of ATV, SIM, GEM, and FEN were 0.157, 0.268, 0.691, and 0.852, respectively. The linearity range is between 100–1500 ng/band for ATV and FEN and 200–3000 ng/band for SIM and GEM, respectively. The accuracy was found to be in the range of 97%–105%. The relative standard deviation of precision and robustness was found to be < 5%. However, the five screened market samples did not show the presence of adulteration of the above drugs. This method for the simultaneous determination of four drugs may be successfully employed to screen synthetic hypolipidemics as adulterants in herbal products and dietary supplements.","PeriodicalId":21639,"journal":{"name":"SEPARATION SCIENCE PLUS","volume":null,"pages":null},"PeriodicalIF":1.3000,"publicationDate":"2023-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"SEPARATION SCIENCE PLUS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/sscp.202300165","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Adulterating herbal medicine with undeclared synthetic drugs is a worldwide problem that seriously threatens human health. To detect such illicit and not labeled synthetic hypolipidemic substances in herbal medicines, an analytical method to simultaneously identify and quantify atorvastatin (ATV) calcium, simvastatin (SIM), gemfibrozil (GEM), fenofibrate (FEN) belonging to two different classes of drugs (statins and fibrates) was developed based on high‐performance thin‐layer chromatography. The method consisted of Silica Gel G60 F 254 precoated aluminum plate as stationary phase and toluene: ethyl acetate: formic acid (7:3:0.3, v/v/v) as optimized mobile phase. The densitometric evaluation wavelength was optimized at 254 nm. The Rf values of ATV, SIM, GEM, and FEN were 0.157, 0.268, 0.691, and 0.852, respectively. The linearity range is between 100–1500 ng/band for ATV and FEN and 200–3000 ng/band for SIM and GEM, respectively. The accuracy was found to be in the range of 97%–105%. The relative standard deviation of precision and robustness was found to be < 5%. However, the five screened market samples did not show the presence of adulteration of the above drugs. This method for the simultaneous determination of four drugs may be successfully employed to screen synthetic hypolipidemics as adulterants in herbal products and dietary supplements.
高效薄层色谱法检测中药产品中合成降脂掺假物
摘要以未经申报的合成药物掺假中药材是严重威胁人类健康的世界性问题。为了检测中草药中非法和未标记的合成降血脂物质,建立了一种基于高效薄层色谱法同时鉴定和定量阿托伐他汀(ATV)钙、辛伐他汀(SIM)、吉非纤维齐(GEM)、非诺贝特(FEN)两类药物(他汀类药物和贝特类药物)的分析方法。该方法以硅胶g60f254预涂铝板为固定相,甲苯:乙酸乙酯:甲酸(7:3:3 .3,v/v/v)为优化流动相。密度评价波长优选为254 nm。ATV、SIM、GEM、FEN的Rf值分别为0.157、0.268、0.691、0.852。ATV和FEN的线性范围分别为100-1500 ng/波段,SIM和GEM的线性范围为200-3000 ng/波段。准确度在97% ~ 105%之间。精密度和稳健性的相对标准偏差为<5%. 但经筛选的5个市场样本均未发现上述药品存在掺假现象。同时测定四种药物的方法可成功地用于筛选草药产品和膳食补充剂中作为掺假物的合成低脂药。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
SEPARATION SCIENCE PLUS
SEPARATION SCIENCE PLUS CHEMISTRY, ANALYTICAL-
CiteScore
1.90
自引率
9.10%
发文量
111
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信