{"title":"Observation of the Curative Effect of Recombinant Human Interferon <i>α</i>2b Gel Combined with LEEP Knife in Cervicitis Caused by IUD and The Effect of Copper/Low-Density Polyethylene Nanocomposite IUD","authors":"Wei Huang, Shanshan Lu, Ling Chen, Ying Lin","doi":"10.1166/jbn.2023.3648","DOIUrl":null,"url":null,"abstract":"In this study, we explored the curative effect of recombinant human interferon α 2b gel combined with a loop electrosurgical excision procedure (LEEP) knife to treat cervicitis. We also analyzed the clinical applications of a copper/low-density polyethylene nanocomposite intrauterine device (IUD). We selected 62 patients with IUD-induced cervicitis admitted to our hospital from March 2020 to December 2022 and divided them into experimental and control groups according to the random number table method ( n = 31/group). The control group was treated with recombinant human interferon α 2b gel only, while the experimental group was treated using a combination of the gel and LEEP knife. We compared the total efficacy rate of both treatments by recording the serum inflammatory cytokines levels, hospitalization, and vaginal drainage times before and after three months of treatment. We selected 50 married women of childbearing age who came to our hospital voluntarily to receive IUDs during the same period and randomly divided them into two groups ( n = 25/group). Each group was administered either a copper/low-density polyethylene (Cu/LDPE) nanocomposite intrauterine device (IUD) or a TCu220C IUD. We conducted follow-ups at three, six, and 12 months after the implantation and analyzed the clinical and side effects. We observed that the total efficacy rate of the cervicitis treatment in the experimental group was 93%, 72% higher than in the control group. After six months of treatment, the tumor necrosis factor- α (TNF- α ), hypersensitive C-reactive protein (hs-CRP), and interleukin-6 (IL-6) levels, and the leukocyte counts of both groups were lower than that before treatment, with the test group showing lower values than the control group. Simultaneously, the hospitalization and vaginal discharge times of the experimental group were lower than those of the control group. We also followed up on the two different IUD groups after three, six, and 12 months. Compared with TCu220C IUD, the Cu/LDPE nanocomposite IUD group showed lesser side effects, such as uterine bleeding and abdominal pain. There was no significant difference between the hemoglobin levels of both groups before and after IUD insertion. In conclusion, recombinant human interferon α 2b gel combined with a LEEP knife is effective in treating cervicitis patients and can control the levels of inflammatory factors in the body. This treatment was safer and quicker and shortened the vaginal discharge time. Additionally, the clinical acceptance of Cu/LDPE nanocomposite IUD for human intrauterine contraception is good due to the low occurrence of adverse reactions, such as uterine bleeding and pain. Therefore, it should be promoted in clinical gynecological practice.","PeriodicalId":15260,"journal":{"name":"Journal of biomedical nanotechnology","volume":"24 1","pages":"0"},"PeriodicalIF":2.9000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of biomedical nanotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1166/jbn.2023.3648","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we explored the curative effect of recombinant human interferon α 2b gel combined with a loop electrosurgical excision procedure (LEEP) knife to treat cervicitis. We also analyzed the clinical applications of a copper/low-density polyethylene nanocomposite intrauterine device (IUD). We selected 62 patients with IUD-induced cervicitis admitted to our hospital from March 2020 to December 2022 and divided them into experimental and control groups according to the random number table method ( n = 31/group). The control group was treated with recombinant human interferon α 2b gel only, while the experimental group was treated using a combination of the gel and LEEP knife. We compared the total efficacy rate of both treatments by recording the serum inflammatory cytokines levels, hospitalization, and vaginal drainage times before and after three months of treatment. We selected 50 married women of childbearing age who came to our hospital voluntarily to receive IUDs during the same period and randomly divided them into two groups ( n = 25/group). Each group was administered either a copper/low-density polyethylene (Cu/LDPE) nanocomposite intrauterine device (IUD) or a TCu220C IUD. We conducted follow-ups at three, six, and 12 months after the implantation and analyzed the clinical and side effects. We observed that the total efficacy rate of the cervicitis treatment in the experimental group was 93%, 72% higher than in the control group. After six months of treatment, the tumor necrosis factor- α (TNF- α ), hypersensitive C-reactive protein (hs-CRP), and interleukin-6 (IL-6) levels, and the leukocyte counts of both groups were lower than that before treatment, with the test group showing lower values than the control group. Simultaneously, the hospitalization and vaginal discharge times of the experimental group were lower than those of the control group. We also followed up on the two different IUD groups after three, six, and 12 months. Compared with TCu220C IUD, the Cu/LDPE nanocomposite IUD group showed lesser side effects, such as uterine bleeding and abdominal pain. There was no significant difference between the hemoglobin levels of both groups before and after IUD insertion. In conclusion, recombinant human interferon α 2b gel combined with a LEEP knife is effective in treating cervicitis patients and can control the levels of inflammatory factors in the body. This treatment was safer and quicker and shortened the vaginal discharge time. Additionally, the clinical acceptance of Cu/LDPE nanocomposite IUD for human intrauterine contraception is good due to the low occurrence of adverse reactions, such as uterine bleeding and pain. Therefore, it should be promoted in clinical gynecological practice.
重组人干扰素α2b凝胶联合LEEP刀治疗宫内节育器所致宫颈炎的疗效观察及铜/低密度聚乙烯纳米复合宫内节育器的效果观察
在本研究中,我们探讨了重组人干扰素α 2b凝胶联合环形电切刀治疗宫颈炎的疗效。我们还分析了铜/低密度聚乙烯纳米复合宫内节育器(IUD)的临床应用。选择2020年3月至2022年12月在我院住院的宫内节育器致宫颈炎患者62例,按随机数字表法分为实验组和对照组(n = 31/组)。对照组采用重组人干扰素α 2b凝胶治疗,实验组采用重组人干扰素α 2b凝胶与LEEP刀联合治疗。我们通过记录治疗前后3个月的血清炎症因子水平、住院率和阴道引流次数来比较两种治疗的总有效率。选择同期来我院自愿接受宫内节育器的已婚育龄妇女50名,随机分为两组(n = 25/组)。各组分别给予铜/低密度聚乙烯(Cu/LDPE)纳米复合宫内节育器(IUD)或TCu220C宫内节育器。我们在植入后3个月、6个月和12个月进行了随访,并分析了临床和副作用。我们观察到,试验组治疗宫颈炎的总有效率为93%,比对照组高72%。治疗6个月后,两组患者肿瘤坏死因子- α (TNF- α)、超敏c反应蛋白(hs-CRP)、白细胞介素-6 (IL-6)水平及白细胞计数均低于治疗前,且试验组低于对照组。同时,实验组住院次数和阴道分泌物次数均低于对照组。我们还在3个月、6个月和12个月后对两个不同的宫内节育器组进行了随访。与TCu220C节育器相比,Cu/LDPE纳米复合节育器组子宫出血、腹痛等副作用较小。两组患者在植入节育器前后血红蛋白水平差异无统计学意义。综上所述,重组人干扰素α 2b凝胶联合LEEP刀治疗宫颈炎患者有效,可控制机体炎症因子水平。该方法安全快捷,缩短了阴道分泌物时间。此外,Cu/LDPE纳米复合宫内节育器用于人宫内避孕的不良反应发生率低,如子宫出血、疼痛等,临床接受度较好。因此,应在临床妇科实践中推广。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.30
自引率
17.20%
发文量
145
审稿时长
2.3 months
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信