Influence of infectious diseases on detection of antibodies to treponema pallidum

V. S. Kuznetsova, N. N. Kiseleva, D. A. Voshchinkina, V. P. Mudrov
{"title":"Influence of infectious diseases on detection of antibodies to treponema pallidum","authors":"V. S. Kuznetsova, N. N. Kiseleva, D. A. Voshchinkina, V. P. Mudrov","doi":"10.33667/2078-5631-2023-23-53-56","DOIUrl":null,"url":null,"abstract":"The problem of the spread of syphilis is becoming acute due to the rapid increase in the number of initially detected cases of the disease. When analyzing and interpreting the obtained laboratory data, there is always the possibility of obtaining contradictory results, both false positive and false negative, which do not coincide with the clinical picture of the patient. Since in practice false positive results of serological tests for syphilis are detected more often than false negative ones, special importance is attached to the identification and study of the causes of their occurrence. At the analysis stage, the cause may be the cross-reactivity of the test system with various ‘particles’ in the analyzed samples, due to the peculiarities of its design and antigenic composition. For this work, sets of reagents Abbott GmbH (CMIA), Mindray (CLIA), as well as reagents produced by Vector-Best (ELISA) were used. During the study, it was found that one of the possible ‘particles’ leading to cross-reactivity of test systems may be IgG antibodies to cytomegalovirus.","PeriodicalId":499576,"journal":{"name":"Medicinskij alfavit","volume":"6 7","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicinskij alfavit","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33667/2078-5631-2023-23-53-56","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The problem of the spread of syphilis is becoming acute due to the rapid increase in the number of initially detected cases of the disease. When analyzing and interpreting the obtained laboratory data, there is always the possibility of obtaining contradictory results, both false positive and false negative, which do not coincide with the clinical picture of the patient. Since in practice false positive results of serological tests for syphilis are detected more often than false negative ones, special importance is attached to the identification and study of the causes of their occurrence. At the analysis stage, the cause may be the cross-reactivity of the test system with various ‘particles’ in the analyzed samples, due to the peculiarities of its design and antigenic composition. For this work, sets of reagents Abbott GmbH (CMIA), Mindray (CLIA), as well as reagents produced by Vector-Best (ELISA) were used. During the study, it was found that one of the possible ‘particles’ leading to cross-reactivity of test systems may be IgG antibodies to cytomegalovirus.
传染病对梅毒螺旋体抗体检测的影响
由于最初发现的梅毒病例数量迅速增加,梅毒传播的问题正变得日益严重。在分析和解释获得的实验室数据时,总是有可能得到矛盾的结果,假阳性和假阴性,这与患者的临床情况不一致。由于在实践中,梅毒血清学检测的假阳性结果比假阴性结果更常被发现,因此特别重视查明和研究其发生的原因。在分析阶段,原因可能是由于其设计和抗原组成的特殊性,测试系统与被分析样品中的各种“颗粒”发生交叉反应。在这项工作中,使用了雅培公司(CMIA)、迈瑞公司(CLIA)的试剂,以及Vector-Best (ELISA)生产的试剂。在研究过程中,发现导致检测系统交叉反应的可能“颗粒”之一可能是巨细胞病毒IgG抗体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信