Association between Blood Group and Change in Coagulation Factors in Plasma Preparations for Transfusion Purpose at Kisii Teaching and Referral Hospital

Q3 Medicine
Collince Odiwuor Ogolla, Benson Nyanchongi, Rodgers Norman Demba
{"title":"Association between Blood Group and Change in Coagulation Factors in Plasma Preparations for Transfusion Purpose at Kisii Teaching and Referral Hospital","authors":"Collince Odiwuor Ogolla, Benson Nyanchongi, Rodgers Norman Demba","doi":"10.1155/2023/3749773","DOIUrl":null,"url":null,"abstract":"Background. Blood component therapy helps in managing patients with reduced hematopoiesis, elevated peripheral destruction of cells, and generalized blood loss (bleeding). Increased prevalence of arterial and venous thrombotic disease linked to the impact of ABO blood group on plasma levels of coagulation glycoprotein is demonstrated by blood group non-O persons. Objective. This study had a main objective of determining the association between blood group and change in coagulation factors in plasma preparation for transfusion purpose. Methods. The study employed a longitudinal study design. Factor assay evaluation was done by the use of Erba Mannheim ECL 105 semiautomated coagulation analyzer from India. Thawing meant for consequent coagulation factor analysis and sequential testing of stored cryoprecipitate and fresh frozen plasma was performed by the use of Stericox plasma thawing bath before being analyzed by the coagulation analyzer. Blood group of the collected blood sample in purple EDTA vacutainer was analyzed using blood antisera and a clean white tile, and results were recorded which helped in establishing the association existing between plasma and blood group. The data were fed into Excel and were evaluated by the use of SPSS version 25. Results. There was no significant association between coagulation factors in fresh frozen plasma and blood group, coagulation factors in cryoprecipitate plasma and blood group of the donors showed that the relationship was not significant with, (r = −0.116, −0.097, 0.007 and 0.047 with <math xmlns=\"http://www.w3.org/1998/Math/MathML\" id=\"M1\"> <mi>p</mi> </math> value (0.900, 0.087, 0.096 and 0.096), respectively, which are greater than 0.005 standard alpha value. Conclusion. This study has shown no significant association existing between blood group and change in coagulation factors in plasma preparations at Kisii Teaching and Referral Hospital.","PeriodicalId":7325,"journal":{"name":"Advances in Hematology","volume":" 5","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Hematology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2023/3749773","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background. Blood component therapy helps in managing patients with reduced hematopoiesis, elevated peripheral destruction of cells, and generalized blood loss (bleeding). Increased prevalence of arterial and venous thrombotic disease linked to the impact of ABO blood group on plasma levels of coagulation glycoprotein is demonstrated by blood group non-O persons. Objective. This study had a main objective of determining the association between blood group and change in coagulation factors in plasma preparation for transfusion purpose. Methods. The study employed a longitudinal study design. Factor assay evaluation was done by the use of Erba Mannheim ECL 105 semiautomated coagulation analyzer from India. Thawing meant for consequent coagulation factor analysis and sequential testing of stored cryoprecipitate and fresh frozen plasma was performed by the use of Stericox plasma thawing bath before being analyzed by the coagulation analyzer. Blood group of the collected blood sample in purple EDTA vacutainer was analyzed using blood antisera and a clean white tile, and results were recorded which helped in establishing the association existing between plasma and blood group. The data were fed into Excel and were evaluated by the use of SPSS version 25. Results. There was no significant association between coagulation factors in fresh frozen plasma and blood group, coagulation factors in cryoprecipitate plasma and blood group of the donors showed that the relationship was not significant with, (r = −0.116, −0.097, 0.007 and 0.047 with p value (0.900, 0.087, 0.096 and 0.096), respectively, which are greater than 0.005 standard alpha value. Conclusion. This study has shown no significant association existing between blood group and change in coagulation factors in plasma preparations at Kisii Teaching and Referral Hospital.
基思教学转诊医院输血用血浆制剂中凝血因子变化与血型的关系
背景。血液成分疗法有助于治疗造血功能减少、外周细胞破坏升高和全身性失血(出血)的患者。非o型血的人证实了ABO血型对血浆凝血糖蛋白水平的影响与动脉和静脉血栓形成疾病的患病率增加有关。目标。本研究的主要目的是确定输血血浆制备中血型与凝血因子变化之间的关系。方法。本研究采用纵向研究设计。采用印度Erba Mannheim ECL 105半自动凝血分析仪进行因子分析。使用Stericox等离子体解冻浴对储存的冷冻沉淀和新鲜冷冻血浆进行解冻,用于随后的凝血因子分析和顺序测试,然后使用凝血分析仪进行分析。对紫色EDTA真空抽采器采集的血样,用抗血清和干净的白色瓷砖进行血型分析,并记录结果,有助于建立血浆与血型之间的关系。将数据输入Excel,并使用SPSS版本25进行评估。结果。新鲜冷冻血浆凝血因子与献血者血型无显著相关性,低温沉淀血浆凝血因子与献血者血型无显著相关性(r = - 0.116、- 0.097、0.007、0.047,p值分别为0.900、0.087、0.096、0.096),均大于0.005标准α值。结论。本研究显示基思教学转诊医院血浆制剂中凝血因子变化与血型无显著相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Advances in Hematology
Advances in Hematology Medicine-Hematology
CiteScore
3.30
自引率
0.00%
发文量
10
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信