Revision of ISO 226 “Normal Equal-Loudness-Level Contours” from 2003 to 2023 edition: the background and results

Pub Date : 2023-01-01 DOI:10.1250/ast.e23.66
Yôiti Suzuki, Hisashi Takeshima, Kenji Kurakata
{"title":"Revision of ISO 226 “Normal Equal-Loudness-Level Contours” from 2003 to 2023 edition: the background and results","authors":"Yôiti Suzuki, Hisashi Takeshima, Kenji Kurakata","doi":"10.1250/ast.e23.66","DOIUrl":null,"url":null,"abstract":"As significant errors were reported in 1985 for the international standard related to equal-loudness-level contours (ELLCs) for pure tones, the earlier international standard was fully revised in 2003 as ISO 226:2003, after 18 years of revision work. Twenty years later, the standard has been revised again as ISO 226:2023. One motivation for the revision was to reflect the lowering of the threshold of hearing at 20 Hz by 0.4 dB in ISO 389-7:2019. In addition, the following two points of substance were revised: (1) implementation of the power exponent relating loudness perception to physical intensity formulated in an academic paper published in 2004, which describes the derivation of ELLCs relating to ISO 226:2003, and (2) adoption of mathematical expressions that preserve the appropriate number of significant digits. In this review, the process of the revision and the technical details of the changes are described. The differences from the 2003 edition are only 0.6 dB at most, and the 2023 standard can be regarded as the same as the 2003 edition in terms of practical use.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1250/ast.e23.66","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

As significant errors were reported in 1985 for the international standard related to equal-loudness-level contours (ELLCs) for pure tones, the earlier international standard was fully revised in 2003 as ISO 226:2003, after 18 years of revision work. Twenty years later, the standard has been revised again as ISO 226:2023. One motivation for the revision was to reflect the lowering of the threshold of hearing at 20 Hz by 0.4 dB in ISO 389-7:2019. In addition, the following two points of substance were revised: (1) implementation of the power exponent relating loudness perception to physical intensity formulated in an academic paper published in 2004, which describes the derivation of ELLCs relating to ISO 226:2003, and (2) adoption of mathematical expressions that preserve the appropriate number of significant digits. In this review, the process of the revision and the technical details of the changes are described. The differences from the 2003 edition are only 0.6 dB at most, and the 2023 standard can be regarded as the same as the 2003 edition in terms of practical use.
分享
查看原文
2003年至2023年版ISO 226“正常等响度级轮廓”的修订:背景和结果
由于1985年国际标准中有关纯音等响度级轮廓(ELLCs)的重大错误,经过18年的修订工作,早前的国际标准于2003年被全面修订为ISO 226:2003。二十年后,该标准再次修订为ISO 226:2023。修订的一个动机是反映ISO 389- 7:19 19将20 Hz的听力阈值降低0.4 dB。此外,对以下两点内容进行了修订:(1)实施了2004年发表的一篇学术论文中制定的与响度感知与物理强度相关的功率指数,该论文描述了与ISO 226:2003相关的ellc的推导,以及(2)采用了保留适当有效数字的数学表达式。在这篇综述中,描述了修订的过程和技术细节的变化。与2003版的差异最多只有0.6 dB,在实际使用方面,2023标准可视为与2003版相同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信