Biomechanical Uniaxial Analysis of Porcine Tendon in the CellScale BioTester® 5000

Alexandru Fofiu, Emil M. Arbănaşi, Robert G. Tripon, Shuko Suzuki, Traian V. Chirilă, Tiberiu Băţagă
{"title":"Biomechanical Uniaxial Analysis of Porcine Tendon in the CellScale BioTester® 5000","authors":"Alexandru Fofiu, Emil M. Arbănaşi, Robert G. Tripon, Shuko Suzuki, Traian V. Chirilă, Tiberiu Băţagă","doi":"10.2478/jim-2023-0009","DOIUrl":null,"url":null,"abstract":"Abstract Background The study was aimed to evaluate whether a mechanical biaxial tester can be used in a uniaxial mode to evaluate the mechanical properties of tendons. Materials and methods The study was carried out on specimens of porcine superficial digital flexor tendon (n = 9). The mechanical properties (elastic modulus, and stress at 15% strain) were measured two times consecutively in the uniaxial mode with the BioTester® 5000 (CellScale) equipment. Results Values of 0.313 ± 0.096 MPa for the elastic (Young’s) modulus and of 0.702 ± 0.174 MPa for the stress (at 15% strain) were measured, indicating that the porcine superficial digital flexor tendon is not a strong tendon. Conclusions When suitable specimens cannot be obtained for a biaxial evaluation, tendons can be evaluated mechanically in the BioTester® 5000 employing the uniaxial mode.","PeriodicalId":234618,"journal":{"name":"Journal of Interdisciplinary Medicine","volume":"124 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Interdisciplinary Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/jim-2023-0009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background The study was aimed to evaluate whether a mechanical biaxial tester can be used in a uniaxial mode to evaluate the mechanical properties of tendons. Materials and methods The study was carried out on specimens of porcine superficial digital flexor tendon (n = 9). The mechanical properties (elastic modulus, and stress at 15% strain) were measured two times consecutively in the uniaxial mode with the BioTester® 5000 (CellScale) equipment. Results Values of 0.313 ± 0.096 MPa for the elastic (Young’s) modulus and of 0.702 ± 0.174 MPa for the stress (at 15% strain) were measured, indicating that the porcine superficial digital flexor tendon is not a strong tendon. Conclusions When suitable specimens cannot be obtained for a biaxial evaluation, tendons can be evaluated mechanically in the BioTester® 5000 employing the uniaxial mode.
用CellScale BioTester®5000进行猪肌腱的生物力学单轴分析
摘要背景本研究旨在评估是否可以在单轴模式下使用力学双轴测试仪来评估肌腱的力学性能。材料与方法本研究采用猪指浅屈肌腱(n = 9)标本,利用BioTester®5000 (CellScale)设备在单轴模式下连续两次测量其力学性能(弹性模量和15%应变下的应力)。结果猪指浅屈肌腱弹性模量为0.313±0.096 MPa,应力模量为0.702±0.174 MPa(15%应变),表明猪指浅屈肌腱不是强肌腱。当无法获得合适的标本进行双轴评估时,可以在BioTester®5000中采用单轴模式对肌腱进行机械评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信