{"title":"Electrochemical Study of Clopidogrel and its Determination in Pharmaceutical Preparations Using Square Wave Voltammetry","authors":"YILMAZ, Bilal\n , YILMAZ, Semih\n ","doi":"10.17776/csj.1282586","DOIUrl":null,"url":null,"abstract":"In the present study, the electroanalytical behaviour of clopidogrel was investigated by cyclic voltammetry method. The procedure was based on clopidogrel being electrochemically oxidized at a platinum electrode in nonaqueous solutions. At 1.93 V, the oxidation peak was noted. It was discovered that clopidogrel's oxidation was diffusion-controlled. Additionally, a quick and easy SWV approach was developed and validated in this work to determine clopidogrel in pharmaceutical preparations. At concentrations between 5 and 50 µg/mL, the calibration curve was linear. The precision was given by relative standard deviation and was less than 2.73%. Accuracy was given with relative error and did not exceed 3.89%. In pharmaceutical preparations, clopidogrel had an average recovery of 100.1%. Under the chosen experimental conditions, no interference was found. The suggested method is extremely accurate and precise. Therefore, the method is applicable to the measurement of clopidogrel in pharmaceutical formulations.","PeriodicalId":10906,"journal":{"name":"Cumhuriyet Science Journal","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cumhuriyet Science Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17776/csj.1282586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In the present study, the electroanalytical behaviour of clopidogrel was investigated by cyclic voltammetry method. The procedure was based on clopidogrel being electrochemically oxidized at a platinum electrode in nonaqueous solutions. At 1.93 V, the oxidation peak was noted. It was discovered that clopidogrel's oxidation was diffusion-controlled. Additionally, a quick and easy SWV approach was developed and validated in this work to determine clopidogrel in pharmaceutical preparations. At concentrations between 5 and 50 µg/mL, the calibration curve was linear. The precision was given by relative standard deviation and was less than 2.73%. Accuracy was given with relative error and did not exceed 3.89%. In pharmaceutical preparations, clopidogrel had an average recovery of 100.1%. Under the chosen experimental conditions, no interference was found. The suggested method is extremely accurate and precise. Therefore, the method is applicable to the measurement of clopidogrel in pharmaceutical formulations.