Kanyinda Kabuya, Oludolapo Akanni Olanrewaju, Ian Joseph Lazarus
{"title":"IMPROVING ENERGY USAGE IN COMMERCIAL BUILDINGS USING SIX SIGMA DMAIC","authors":"Kanyinda Kabuya, Oludolapo Akanni Olanrewaju, Ian Joseph Lazarus","doi":"10.7166/34-2-2392","DOIUrl":null,"url":null,"abstract":"This article describes the energy-saving measures in commercial buildings from different perspectives on energy saving in cities. In recent years, improving energy conservation in commercial buildings has become an issue of great importance for the financial well-being of organisations. The study uses the define-measure-analyze-improve-control (DMAIC) Six Sigma approach to identify the factors that contribute to increases in electricity consumption. With the increasing shortage of energy, two years’ worth of energy consumption data from a commercial building in South Africa was collected and analyzed using statistical tools. The research findings revealed that the boiler had the highest electricity consumption (38.33 per cent), followed by the kitchen (24.20 per cent) and the rest of the building (37.47 per cent). After applying the DMAIC process, it showed that the electricity consumption of the boiler could be reduced by 6 per cent during the improvement phase. Keywords: Six Sigma, DMAIC, Energy management, Energy consumption, Energy efficiency","PeriodicalId":49493,"journal":{"name":"South African Journal of Industrial Engineering","volume":"25 1","pages":"0"},"PeriodicalIF":0.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"South African Journal of Industrial Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7166/34-2-2392","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, INDUSTRIAL","Score":null,"Total":0}
引用次数: 0
Abstract
This article describes the energy-saving measures in commercial buildings from different perspectives on energy saving in cities. In recent years, improving energy conservation in commercial buildings has become an issue of great importance for the financial well-being of organisations. The study uses the define-measure-analyze-improve-control (DMAIC) Six Sigma approach to identify the factors that contribute to increases in electricity consumption. With the increasing shortage of energy, two years’ worth of energy consumption data from a commercial building in South Africa was collected and analyzed using statistical tools. The research findings revealed that the boiler had the highest electricity consumption (38.33 per cent), followed by the kitchen (24.20 per cent) and the rest of the building (37.47 per cent). After applying the DMAIC process, it showed that the electricity consumption of the boiler could be reduced by 6 per cent during the improvement phase. Keywords: Six Sigma, DMAIC, Energy management, Energy consumption, Energy efficiency
期刊介绍:
The South African Journal of Industrial Engineering (SAJIE) publishes articles with the emphasis on research, development and application within the fields of Industrial Engineering and Engineering and Technology Management. In this way, it aims to contribute to the further development of these fields of study and to serve as a vehicle for the effective interchange of knowledge, ideas and experience between the research and training oriented institutions and the application oriented industry. Articles on practical applications, original research and meaningful new developments as well as state of the art surveys are encouraged.