Analysis and control of large shunt capacitor bank switching transients

J. Das
{"title":"Analysis and control of large shunt capacitor bank switching transients","authors":"J. Das","doi":"10.1109/PAPCON.2005.1502059","DOIUrl":null,"url":null,"abstract":"Large capacitor banks at medium voltage levels are finding applications and greater acceptability in industrial distribution systems. However, these can give rise to current and voltage transients, stress the switching devices and insulation systems, and can be detrimental to the sensitive loads, i.e., drive systems. The paper discusses the methodology of the analysis and control of the switching transients. The results of EMTP simulation are presented, where applicable","PeriodicalId":314450,"journal":{"name":"Conference Record of 2005 Annual Pulp and Paper Industry Technical Conference, 2005.","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"53","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of 2005 Annual Pulp and Paper Industry Technical Conference, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PAPCON.2005.1502059","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 53

Abstract

Large capacitor banks at medium voltage levels are finding applications and greater acceptability in industrial distribution systems. However, these can give rise to current and voltage transients, stress the switching devices and insulation systems, and can be detrimental to the sensitive loads, i.e., drive systems. The paper discusses the methodology of the analysis and control of the switching transients. The results of EMTP simulation are presented, where applicable
大型并联电容器组开关暂态分析与控制
中压水平的大型电容器组正在工业配电系统中寻找应用和更大的可接受性。然而,这些会引起电流和电压瞬变,对开关设备和绝缘系统造成压力,并且可能对敏感负载(即驱动系统)有害。本文讨论了开关暂态的分析和控制方法。在适当的情况下,给出了EMTP仿真结果
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信