[Mixed venous versus central venous oxygen saturation in intensive medicine].

M Wendt, T Hachenberg, A Albert, R Janzen
{"title":"[Mixed venous versus central venous oxygen saturation in intensive medicine].","authors":"M Wendt,&nbsp;T Hachenberg,&nbsp;A Albert,&nbsp;R Janzen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Mixed venous oxygen saturation (SvO2) has been established as a useful guide in observing whole body oxygenation. Since SvO2 provides limited information about adequate tissue oxygenation for a specific organ, the usefulness of central venous saturation (ScvO2) as a guide was analysed, which is a less invasive parameter. In 19 ICU patients 44 pairs of blood samples were drawn from a separate central venous catheter and from the tip of an SG-catheter. The correlation of oxygen partial pressures was 0.687 and the correlation of the saturation reached 0.779. The calculation of venous admixture showed a correlation of 0.901. It is concluded that ScvO2 yields adequate information on the oxygen saturation of venous return.</p>","PeriodicalId":7813,"journal":{"name":"Anasthesie, Intensivtherapie, Notfallmedizin","volume":"25 1","pages":"102-6"},"PeriodicalIF":0.0000,"publicationDate":"1990-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Anasthesie, Intensivtherapie, Notfallmedizin","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Mixed venous oxygen saturation (SvO2) has been established as a useful guide in observing whole body oxygenation. Since SvO2 provides limited information about adequate tissue oxygenation for a specific organ, the usefulness of central venous saturation (ScvO2) as a guide was analysed, which is a less invasive parameter. In 19 ICU patients 44 pairs of blood samples were drawn from a separate central venous catheter and from the tip of an SG-catheter. The correlation of oxygen partial pressures was 0.687 and the correlation of the saturation reached 0.779. The calculation of venous admixture showed a correlation of 0.901. It is concluded that ScvO2 yields adequate information on the oxygen saturation of venous return.

[重症医学中混合静脉与中心静脉血氧饱和度]。
混合静脉氧饱和度(SvO2)已被确立为观察全身氧合的有用指标。由于SvO2提供的关于特定器官足够组织氧合的信息有限,因此分析了中心静脉饱和度(ScvO2)作为指导的有效性,这是一个侵入性较小的参数。在19例ICU患者中,从单独的中心静脉导管和sg导管尖端抽取了44对血液样本。氧分压的相关系数为0.687,饱和度的相关系数为0.779。静脉掺合量的计算结果显示相关性为0.901。由此得出结论,ScvO2能提供足够的静脉回流血氧饱和度信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信