{"title":"Precision audio nulling instrumentation achieves near −140dB measurements in a production environment","authors":"Carl Karandjeff, Chris Hannaford","doi":"10.1109/TEST.2010.5699262","DOIUrl":null,"url":null,"abstract":"This paper describes a novel precision audio measurement instrument, the Data Converter Test Module (DCTM), which utilizes a “two pass” measurement technique for the precision measurement of AC sine waves. The two-pass technique can measure near −140dB THD in less than 20ms in a production environment.","PeriodicalId":265156,"journal":{"name":"2010 IEEE International Test Conference","volume":"161 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2010-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2010 IEEE International Test Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TEST.2010.5699262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
This paper describes a novel precision audio measurement instrument, the Data Converter Test Module (DCTM), which utilizes a “two pass” measurement technique for the precision measurement of AC sine waves. The two-pass technique can measure near −140dB THD in less than 20ms in a production environment.