{"title":"Study of the behaviour of partial discharges for proactive diagnostics in medium voltage cables","authors":"M. Shafiq, I. Kiitam, P. Taklaja, M. Parker, I. Palu, L. Kütt","doi":"10.1109/PowerAfrica52236.2021.9543233","DOIUrl":null,"url":null,"abstract":"The use of power cables is increasing worldwide. Aging and insulation degradation reduce the in-service lifetime of a power cable. Effective partial discharge (PD) analysis can quantify the stage of the insulation damage. This paper presents a study on the PD behavior prior to possible breakdown of a medium voltage (MV) cable. An artificial defect was introduced into the insulation of the cable sample. Electrical stress is applied across the sample and increased until the breakdown occurred. PD activity is monitored and time-domain analysis is performed to study the behavior of PD characteristics. During increased electric stress, the pattern of the PD characteristics such as pulse amplitude and pulse repetition rate is studied. The analysis of PD inception to breakdown stages provide valuable information to identify the breakdown vicinity. Timely information of the ongoing insulation degradation can help to avoid the sudden failure of the power cables.","PeriodicalId":370999,"journal":{"name":"2021 IEEE PES/IAS PowerAfrica","volume":"62 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE PES/IAS PowerAfrica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PowerAfrica52236.2021.9543233","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The use of power cables is increasing worldwide. Aging and insulation degradation reduce the in-service lifetime of a power cable. Effective partial discharge (PD) analysis can quantify the stage of the insulation damage. This paper presents a study on the PD behavior prior to possible breakdown of a medium voltage (MV) cable. An artificial defect was introduced into the insulation of the cable sample. Electrical stress is applied across the sample and increased until the breakdown occurred. PD activity is monitored and time-domain analysis is performed to study the behavior of PD characteristics. During increased electric stress, the pattern of the PD characteristics such as pulse amplitude and pulse repetition rate is studied. The analysis of PD inception to breakdown stages provide valuable information to identify the breakdown vicinity. Timely information of the ongoing insulation degradation can help to avoid the sudden failure of the power cables.
中压电缆局部放电行为的主动诊断研究
电力电缆的使用在世界范围内不断增加。电缆老化、绝缘劣化会降低电缆的使用寿命。有效局部放电(PD)分析可以量化绝缘损伤的阶段。本文研究了中压(MV)电缆可能击穿前的局部放电行为。在电缆样品的绝缘中引入了人为缺陷。在样品上施加电应力并不断增加,直到发生击穿。监测PD活动,并进行时域分析以研究PD特征的行为。在增加电应力的情况下,研究了脉冲振幅和脉冲重复率等局部放电特性的变化规律。从PD开始到击穿阶段的分析为确定击穿附近提供了有价值的信息。及时了解绝缘劣化情况,可以避免电力电缆突然失效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信