Unbalanced short-circuit calculation by phase coordinates

W. He, C. Teo
{"title":"Unbalanced short-circuit calculation by phase coordinates","authors":"W. He, C. Teo","doi":"10.1109/EMPD.1995.500821","DOIUrl":null,"url":null,"abstract":"This paper demonstrates a direct approach for fault current calculations without using symmetrical components. By representing a polyphase network in phase-coordinates, i.e. phase voltages, currents and impedances, the unbalanced fault currents can also be analyzed and calculated. The proposed approach is direct and can be implemented easily by solving a set of linear system equations. Identical results for both methods are obtained in a sample network. The following faults are analyzed: phase-to-earth with/without impedance; phase-to-phase fault with/without impedance; two-phase-to-earth fault; and a three-phase fault.","PeriodicalId":447674,"journal":{"name":"Proceedings 1995 International Conference on Energy Management and Power Delivery EMPD '95","volume":"52 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1995-11-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings 1995 International Conference on Energy Management and Power Delivery EMPD '95","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EMPD.1995.500821","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

This paper demonstrates a direct approach for fault current calculations without using symmetrical components. By representing a polyphase network in phase-coordinates, i.e. phase voltages, currents and impedances, the unbalanced fault currents can also be analyzed and calculated. The proposed approach is direct and can be implemented easily by solving a set of linear system equations. Identical results for both methods are obtained in a sample network. The following faults are analyzed: phase-to-earth with/without impedance; phase-to-phase fault with/without impedance; two-phase-to-earth fault; and a three-phase fault.
不平衡短路的相位坐标计算
本文演示了一种不使用对称分量计算故障电流的直接方法。通过用相坐标(即相电压、相电流和相阻抗)表示多相网络,还可以对不平衡故障电流进行分析和计算。所提出的方法是直接的,并且可以通过求解一组线性系统方程轻松实现。在一个网络样本中,两种方法得到了相同的结果。分析了以下故障:带/不带阻抗的相地故障;有/无阻抗相对相故障;two-phase-to-earth断层;三相故障。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信