{"title":"Physically-based distributed models for multi-layer ceramic capacitors","authors":"C. Sullivan, Yuqin Sun","doi":"10.1109/EPEP.2003.1250028","DOIUrl":null,"url":null,"abstract":"Measurements show that lumped RLC models for multilayer ceramic capacitors are inadequate. A new transmission-line model offers advantages over previous transmission-line models: a closer fit to measured data, and a physical basis for the model.","PeriodicalId":254477,"journal":{"name":"Electrical Performance of Electrical Packaging (IEEE Cat. No. 03TH8710)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electrical Performance of Electrical Packaging (IEEE Cat. No. 03TH8710)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEP.2003.1250028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12
Abstract
Measurements show that lumped RLC models for multilayer ceramic capacitors are inadequate. A new transmission-line model offers advantages over previous transmission-line models: a closer fit to measured data, and a physical basis for the model.