An analytical characterisation of cold-load pickup oscillations in thermostatically controlled loads

Cristian Perfumo, J. Braslavsky, J. Ward, E. Kofman
{"title":"An analytical characterisation of cold-load pickup oscillations in thermostatically controlled loads","authors":"Cristian Perfumo, J. Braslavsky, J. Ward, E. Kofman","doi":"10.1109/AUCC.2013.6697272","DOIUrl":null,"url":null,"abstract":"Large groups of thermostatically controlled loads can be controlled to achieve the necessary balance between generation and demand in power networks. When a significant portion of a population of thermostatically controlled loads is forced to change their on-off state simultaneously, the aggregate power demand of such population presents large, underdamped oscillations, a well-known phenomenon referred to by power utilities as “cold-load pickup”. Characterising these oscillations and, in general, the aggregate dynamics of the population facilitates mathematical analysis and control design. In this paper we present a stochastic model for the power response and derive simple expressions for the period and envelope of the oscillations.","PeriodicalId":177490,"journal":{"name":"2013 Australian Control Conference","volume":"16 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2013-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Australian Control Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/AUCC.2013.6697272","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Large groups of thermostatically controlled loads can be controlled to achieve the necessary balance between generation and demand in power networks. When a significant portion of a population of thermostatically controlled loads is forced to change their on-off state simultaneously, the aggregate power demand of such population presents large, underdamped oscillations, a well-known phenomenon referred to by power utilities as “cold-load pickup”. Characterising these oscillations and, in general, the aggregate dynamics of the population facilitates mathematical analysis and control design. In this paper we present a stochastic model for the power response and derive simple expressions for the period and envelope of the oscillations.
恒温控制负载中冷负载拾取振荡的解析特性
可以控制大量的恒温控制负载,以实现电网中发电和需求之间的必要平衡。当大量的恒温控制负荷同时被迫改变它们的开关状态时,这些负荷的总电力需求呈现出大的、欠阻尼的振荡,这是一种众所周知的现象,被电力公司称为“冷负荷回升”。描述这些振荡和总体总体动态有助于数学分析和控制设计。本文给出了一个功率响应的随机模型,并推导了周期和包络线的简单表达式。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信