Trigger system changes for the HERMES III accelerator

S. Coffey, B. Lewis, J. Sedillo, J. D. Salazar
{"title":"Trigger system changes for the HERMES III accelerator","authors":"S. Coffey, B. Lewis, J. Sedillo, J. D. Salazar","doi":"10.1109/PPC.2017.8291183","DOIUrl":null,"url":null,"abstract":"This paper describes the hardware changes made to the triggering system of the HERMES III accelerator at Sandia National Laboratories, New Mexico. The HERMES III accelerator is a gamma ray simulator producing 100 kRad dose per shot with a full width half max pulse duration of approximately 25 nanoseconds and averaging six shots per day. For each accelerator test, approximately 400 probe signals are recorded over approximately 65 digitizers. The original digitizer trigger system employed numerous independent legacy signal generators resulting in non-referenceable digitizer time bases. We detail our efforts to reference the digitizer time bases together using a modular and scalable approach with commercial-off-the-shelf components. This upgraded trigger system presently measures a maximum digitizer trigger time spread of less than two nanoseconds across the 65+ digitizers. This document details the hardware changes, provides a summary of the accelerator charging process, presents “one-line” trigger system diagrams and summarizes the times of interest for a typical HERMES accelerator shot.","PeriodicalId":247019,"journal":{"name":"2017 IEEE 21st International Conference on Pulsed Power (PPC)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 21st International Conference on Pulsed Power (PPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2017.8291183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper describes the hardware changes made to the triggering system of the HERMES III accelerator at Sandia National Laboratories, New Mexico. The HERMES III accelerator is a gamma ray simulator producing 100 kRad dose per shot with a full width half max pulse duration of approximately 25 nanoseconds and averaging six shots per day. For each accelerator test, approximately 400 probe signals are recorded over approximately 65 digitizers. The original digitizer trigger system employed numerous independent legacy signal generators resulting in non-referenceable digitizer time bases. We detail our efforts to reference the digitizer time bases together using a modular and scalable approach with commercial-off-the-shelf components. This upgraded trigger system presently measures a maximum digitizer trigger time spread of less than two nanoseconds across the 65+ digitizers. This document details the hardware changes, provides a summary of the accelerator charging process, presents “one-line” trigger system diagrams and summarizes the times of interest for a typical HERMES accelerator shot.
HERMES III加速器的触发系统改变
本文介绍了新墨西哥州桑迪亚国家实验室HERMES III加速器触发系统的硬件改造。HERMES III加速器是一种伽马射线模拟器,每次发射产生100克拉的剂量,全宽一半最大脉冲持续时间约为25纳秒,平均每天发射6次。对于每个加速器测试,大约400个探头信号被记录在大约65个数字化仪上。原始的数字化触发系统采用了许多独立的遗留信号发生器,导致数字化时基不可参考。我们详细介绍了我们使用模块化和可扩展的方法与商业现成组件一起参考数字化时间基础的努力。这个升级的触发系统目前测量的最大数字化触发时间分布小于2纳秒跨越65+数字化仪。本文档详细介绍了硬件变化,提供了加速器充电过程的摘要,提供了“一行”触发系统图,并总结了典型HERMES加速器射击的兴趣时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信