M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk
{"title":"Integral Strategies of Active Filtration in the Reference Frame of the Two-Wattmeters Method","authors":"M. Artemenko, Vasyl Kutafin, Ivan Shapoval, Vasyl Chopyk, V. Mykhalskyi, S. Polishchuk","doi":"10.1109/EUROCON52738.2021.9535637","DOIUrl":null,"url":null,"abstract":"In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.","PeriodicalId":328338,"journal":{"name":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","volume":"416 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE EUROCON 2021 - 19th International Conference on Smart Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EUROCON52738.2021.9535637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In the paper, two integral strategies of active filtration in the reference frame of the two-wattmeters method are proposed, which are different from known ones by the simplicity of implementation, increased accuracy, and speed. The formula for calculating the energy-saving effect from active filtration in a three-phase three-wire power system in the conditions of unbalanced load and line voltages is derived. Experimental studies show that the proposed integral control strategy of active filtration with a reference vector of line asymmetric voltages provides the best energy-saving effect but generates asymmetric mains currents. The most promising is the proposed integral control strategy of active filtering with a reference vector of direct sequence line voltages, which provides almost the same energy-saving effect, symmetric sinusoidal currents of the network, and minimal ripple of power consumption.