{"title":"Revisiting the power-efficiency trade-off on a DC voltage source","authors":"A. F. Jaimes, F. Sousa","doi":"10.1109/LASCAS.2016.7451075","DOIUrl":null,"url":null,"abstract":"When a DC voltage source supplies energy to an electric load, it can operate either for maximum power transfer and low efficiency (50%), or with an acceptable efficiency with less power transferred. In this paper an analytic expression is developed and used to quantify this trade off. Moreover, this expression is validated by an experimental circuit demonstrator.","PeriodicalId":129875,"journal":{"name":"2016 IEEE 7th Latin American Symposium on Circuits & Systems (LASCAS)","volume":"20 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE 7th Latin American Symposium on Circuits & Systems (LASCAS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/LASCAS.2016.7451075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
When a DC voltage source supplies energy to an electric load, it can operate either for maximum power transfer and low efficiency (50%), or with an acceptable efficiency with less power transferred. In this paper an analytic expression is developed and used to quantify this trade off. Moreover, this expression is validated by an experimental circuit demonstrator.