On the optimal electric loads for ultrasound energy receivers

M. Gorostiaga, M. Wapler, U. Wallrabe
{"title":"On the optimal electric loads for ultrasound energy receivers","authors":"M. Gorostiaga, M. Wapler, U. Wallrabe","doi":"10.1109/ISAF.2017.8000206","DOIUrl":null,"url":null,"abstract":"In this paper, we experimentally verify the difference between the zero reflection condition and the power maximization approach for the optimal electric loads. First, we predict those optimal loads with the KLM model for a 1–3 composite transducer that we use as a receiver, and we then perform experiments in deionized water with different ohmic loads attached to it. The measurements confirm that the electric loads that achieve the highest efficiency of the receiver are not equal to the loads that minimize the reflections.","PeriodicalId":421889,"journal":{"name":"2017 Joint IEEE International Symposium on the Applications of Ferroelectric (ISAF)/International Workshop on Acoustic Transduction Materials and Devices (IWATMD)/Piezoresponse Force Microscopy (PFM)","volume":"15 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 Joint IEEE International Symposium on the Applications of Ferroelectric (ISAF)/International Workshop on Acoustic Transduction Materials and Devices (IWATMD)/Piezoresponse Force Microscopy (PFM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISAF.2017.8000206","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In this paper, we experimentally verify the difference between the zero reflection condition and the power maximization approach for the optimal electric loads. First, we predict those optimal loads with the KLM model for a 1–3 composite transducer that we use as a receiver, and we then perform experiments in deionized water with different ohmic loads attached to it. The measurements confirm that the electric loads that achieve the highest efficiency of the receiver are not equal to the loads that minimize the reflections.
超声能量接收器的最佳电负荷
在本文中,我们通过实验验证了零反射条件和功率最大化方法在最优电负荷中的区别。首先,我们用KLM模型预测了我们用作接收器的1-3复合换能器的最佳负载,然后我们在带有不同欧姆负载的去离子水中进行了实验。测量结果证实,使接收器达到最高效率的电负载不等于使反射最小化的负载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信