{"title":"Modelling and Passivity Analysis of VSC Output Impedance under SRF and αβ Control Frames","authors":"K. V. Kkuni, Sujay Ghosh, Guangya Yang, C. Booth","doi":"10.1109/IECON.2019.8927124","DOIUrl":null,"url":null,"abstract":"Passivity property of input impedance of grid connected Voltage Source Converter (VSC) is a good measure for ensuring small signal stability of the power system composed of numerous interconnected dynamical system. It is well known that a pure passivity for a VSC is impossible to obtain, however, if the frequency range of the negative admittance from VSC terminal can be minimized, the possibility instability due to grid side impedance interacting with the VSC system can be reduced. For a VSC, there are two major design alternatives for the current controller;a decoupled dq current controller and αβ frame Proportional Resonant controller. This paper compares these two current controller alternatives for VSC, based on their passivity property. The small signal model of LCL filter equipped VSC with the two types of current controller is also derived. Some design recommendations using the considered current controllers, for reducing non-passive frequency range is also presented.","PeriodicalId":187719,"journal":{"name":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","volume":"134 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IECON 2019 - 45th Annual Conference of the IEEE Industrial Electronics Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IECON.2019.8927124","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Passivity property of input impedance of grid connected Voltage Source Converter (VSC) is a good measure for ensuring small signal stability of the power system composed of numerous interconnected dynamical system. It is well known that a pure passivity for a VSC is impossible to obtain, however, if the frequency range of the negative admittance from VSC terminal can be minimized, the possibility instability due to grid side impedance interacting with the VSC system can be reduced. For a VSC, there are two major design alternatives for the current controller;a decoupled dq current controller and αβ frame Proportional Resonant controller. This paper compares these two current controller alternatives for VSC, based on their passivity property. The small signal model of LCL filter equipped VSC with the two types of current controller is also derived. Some design recommendations using the considered current controllers, for reducing non-passive frequency range is also presented.
SRF和αβ控制框架下VSC输出阻抗建模及无源性分析
并网电压源变换器(VSC)输入阻抗的无源性是保证由多个互联动力系统组成的电力系统小信号稳定性的良好措施。众所周知,VSC的纯无源性是不可能获得的,但是,如果可以最小化VSC终端负导纳的频率范围,则可以减少由于网格侧阻抗与VSC系统相互作用而导致的不稳定的可能性。对于VSC,有两种主要的电流控制器设计方案:解耦dq电流控制器和αβ框架比例谐振控制器。本文从无源性的角度比较了这两种控制方案。并推导了两种电流控制器配置VSC的LCL滤波器的小信号模型。本文还提出了一些使用电流控制器减小非被动频率范围的设计建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信