Calibration scheme for microwave biosensors using exclusively liquid calibration standards

F. Michler, F. Lenze, M. Schusler, R. Jakoby
{"title":"Calibration scheme for microwave biosensors using exclusively liquid calibration standards","authors":"F. Michler, F. Lenze, M. Schusler, R. Jakoby","doi":"10.1109/BIOWIRELESS.2016.7445564","DOIUrl":null,"url":null,"abstract":"In the growing field of biosensing, the dielectric analysis of liquids and cell suspensions has become an important research topic. This paper suggests a novel calibration scheme for capacitive sensors, which exclusively relies on liquids instead of conventional termination standards. Moreover, the influence of several parameters on the reliability of the measurements is investigated by simulation. Finally, the concept of calibration is proven by measurements obtained using three different sensor prototypes.","PeriodicalId":154090,"journal":{"name":"2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","volume":"14 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1900-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/BIOWIRELESS.2016.7445564","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

In the growing field of biosensing, the dielectric analysis of liquids and cell suspensions has become an important research topic. This paper suggests a novel calibration scheme for capacitive sensors, which exclusively relies on liquids instead of conventional termination standards. Moreover, the influence of several parameters on the reliability of the measurements is investigated by simulation. Finally, the concept of calibration is proven by measurements obtained using three different sensor prototypes.
微波生物传感器专用液体校准标准的校准方案
在不断发展的生物传感领域,液体和细胞悬浮液的介电分析已成为一个重要的研究课题。本文提出了一种新的电容式传感器校准方案,该方案完全依赖于液体而不是传统的端接标准。此外,还通过仿真研究了几个参数对测量结果可靠性的影响。最后,通过使用三种不同的传感器原型获得的测量结果验证了校准的概念。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信