{"title":"Comparison of Efficacy of Laryngeal Mask Versus I-Gel Airway Devices","authors":"Asad Zaman, Ameer Hamza, Kaleemullah, Abdul Wahab Dogar, Zahoor Ahmed, Azhar Hussain","doi":"10.52206/jsmc.2023.13.1.712","DOIUrl":null,"url":null,"abstract":"Background: Adequate ventilation is the primary goal of general anesthesia. A variety of supra-glottic airway devices wereintroduced to simplify airway management and minimize complications.Objective: To compare the Laryngeal mask airway versus I-Gel in terms of insertion time, number of successful insertion attempts,and changes in hemodynamic parameters in patients getting general anesthesia.Material and Methods: This comparative study was performed at the Anesthesia department, Pir Abdul Qadir Shah Institute ofMedical Sciences, Gambat from 1st July 2020 to 31st December 2020. Patients achieving the inclusion criteria were divided into twogroups. In Group-A, the I-Gel device was used for airway maintenance; while in Group-B, the Laryngeal Mask Airway(LMA) wasused. The mean insertion time, insertion attempts, and hemodynamic parameters were recorded and compared in both groups.Results: Total number of participants studied was 140; with 70 participants in each group.The mean age was 33.74+6.75 years inGroup-A and 33.16+7.24 years in Group-B. Gender distribution showed 62.86 % (n=44) male in Group-A and 64.29% (n=45) inGroup-B. A comparison of LMA versus I-Gel showed a mean insertion time of 22.81+3.09 seconds in Group-A and 31.53+2.46seconds in Group-B (p<0.0001). The number of successful insertion attempts and the changes in the hemodynamic parameterswas comparable in both groups (p>0.05).Conclusion: This study concluded that the I-Gel device has a significantly low insertion time compared to LMA in elective settings.So, its use can be handy in emergency settings.Keywords: I-Gel, LMA, General anesthesia, insertion time","PeriodicalId":326561,"journal":{"name":"Journal of Saidu Medical College, Swat","volume":"58 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Saidu Medical College, Swat","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52206/jsmc.2023.13.1.712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Adequate ventilation is the primary goal of general anesthesia. A variety of supra-glottic airway devices wereintroduced to simplify airway management and minimize complications.Objective: To compare the Laryngeal mask airway versus I-Gel in terms of insertion time, number of successful insertion attempts,and changes in hemodynamic parameters in patients getting general anesthesia.Material and Methods: This comparative study was performed at the Anesthesia department, Pir Abdul Qadir Shah Institute ofMedical Sciences, Gambat from 1st July 2020 to 31st December 2020. Patients achieving the inclusion criteria were divided into twogroups. In Group-A, the I-Gel device was used for airway maintenance; while in Group-B, the Laryngeal Mask Airway(LMA) wasused. The mean insertion time, insertion attempts, and hemodynamic parameters were recorded and compared in both groups.Results: Total number of participants studied was 140; with 70 participants in each group.The mean age was 33.74+6.75 years inGroup-A and 33.16+7.24 years in Group-B. Gender distribution showed 62.86 % (n=44) male in Group-A and 64.29% (n=45) inGroup-B. A comparison of LMA versus I-Gel showed a mean insertion time of 22.81+3.09 seconds in Group-A and 31.53+2.46seconds in Group-B (p<0.0001). The number of successful insertion attempts and the changes in the hemodynamic parameterswas comparable in both groups (p>0.05).Conclusion: This study concluded that the I-Gel device has a significantly low insertion time compared to LMA in elective settings.So, its use can be handy in emergency settings.Keywords: I-Gel, LMA, General anesthesia, insertion time