Effect of Screw Head- and Hook-on Bond Behavior of Flamingo Shear Reinforcing Technique in Concrete

A. Sh Mahmood, Suhad M. Abd, Isam S. Mhaimeed
{"title":"Effect of Screw Head- and Hook-on Bond Behavior of Flamingo Shear Reinforcing Technique in Concrete","authors":"A. Sh Mahmood, Suhad M. Abd, Isam S. Mhaimeed","doi":"10.24237/djes.2023.16111","DOIUrl":null,"url":null,"abstract":"An alternative reinforcing shear technique was proposed during this work in place of the traditional vertical stirrups. Three reinforced concrete beams with dimensions of (200 * 300) mm and a length of 1800 mm were used. A reference control beam with traditional vertical stirrups (RCWS) and two beams reinforced with flamingo with a fixed angle of 45° and free ends (50% and 50%) from effective depth were used, while the main variable was the bonding process with concrete using a screw head (FWS) and hook (FWH). In the flamingo technique, the hook was used and the screw head was used at an equal angle of 130 degrees. A significant improvement was found in the shear capacity of the beam compared to the reference sample. Also, using a screw head made the shear capacity 13.22% higher than using a hook and improved the shear ductility, final deflection, and crushing behavior of beams made with the flamingo technique.","PeriodicalId":294128,"journal":{"name":"Diyala Journal of Engineering Sciences","volume":"507 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2023-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diyala Journal of Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24237/djes.2023.16111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

An alternative reinforcing shear technique was proposed during this work in place of the traditional vertical stirrups. Three reinforced concrete beams with dimensions of (200 * 300) mm and a length of 1800 mm were used. A reference control beam with traditional vertical stirrups (RCWS) and two beams reinforced with flamingo with a fixed angle of 45° and free ends (50% and 50%) from effective depth were used, while the main variable was the bonding process with concrete using a screw head (FWS) and hook (FWH). In the flamingo technique, the hook was used and the screw head was used at an equal angle of 130 degrees. A significant improvement was found in the shear capacity of the beam compared to the reference sample. Also, using a screw head made the shear capacity 13.22% higher than using a hook and improved the shear ductility, final deflection, and crushing behavior of beams made with the flamingo technique.
火烈鸟剪力加固技术对混凝土螺纹头和钩接粘结性能的影响
在这项工作中,提出了一种替代钢筋剪切技术来代替传统的垂直箍筋。三根钢筋混凝土梁,尺寸为(200 * 300)mm,长度为1800 mm。采用传统垂直马镫(RCWS)的参考控制梁和两根火烈鸟加固梁,固定角度为45°,自由端(50%和50%)来自有效深度,而主要变量是使用螺钉头(FWS)和钩(FWH)与混凝土的粘合过程。在火烈鸟技术中,钩和螺钉头以130度等角使用。与参考样品相比,梁的抗剪能力有了显著的提高。此外,使用螺旋头比使用挂钩提高了13.22%的抗剪能力,并改善了用火烈鸟技术制作的梁的抗剪延性、最终挠度和破碎性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信