{"title":"Impact of measurement system noise figure and gain on emissions measurements above 1 GHz","authors":"W. Atchison","doi":"10.1109/ISEMC.2003.1236620","DOIUrl":null,"url":null,"abstract":"The ability to make weak signal emissions measurements at frequencies above 1 GHz id directly related to system noise figure, which ultimately sets the system noise floor. Contributing factors to the measurement system noise figure are the front-end coax loss, preamplifier noise figure, preamplifier gain, measurement device (spectrum analyzer or receiver) noise figure and measurement system configuration. Attention to the effects of these factors on EMC measurements is generally not understood. The system noise floor will have a major impact on the ability to detect and measure a weak signal. Impact on other factors, such as the introduction of intermodulation products by the preamplifier is not discussed in this paper.","PeriodicalId":359422,"journal":{"name":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","volume":"36 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2003-10-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2003 IEEE Symposium on Electromagnetic Compatibility. Symposium Record (Cat. No.03CH37446)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2003.1236620","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

The ability to make weak signal emissions measurements at frequencies above 1 GHz id directly related to system noise figure, which ultimately sets the system noise floor. Contributing factors to the measurement system noise figure are the front-end coax loss, preamplifier noise figure, preamplifier gain, measurement device (spectrum analyzer or receiver) noise figure and measurement system configuration. Attention to the effects of these factors on EMC measurements is generally not understood. The system noise floor will have a major impact on the ability to detect and measure a weak signal. Impact on other factors, such as the introduction of intermodulation products by the preamplifier is not discussed in this paper.
测量系统噪声系数和增益对1ghz以上发射测量的影响
在1 GHz以上频率下进行微弱信号发射测量的能力与系统噪声系数直接相关,最终确定系统噪声底限。影响测量系统噪声系数的因素有前端同轴损耗、前置放大器噪声系数、前置放大器增益、测量设备(频谱分析仪或接收机)噪声系数和测量系统配置。人们通常不了解这些因素对电磁兼容测量的影响。系统本底噪声将对检测和测量微弱信号的能力产生重大影响。对其他因素的影响,如前置放大器引入互调产物,在本文中没有讨论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信