Analytical design of low-cost wearable servo valve using buckled tubes

Keiichiro Koga, T. Akagi, S. Dohta, A. Nasir
{"title":"Analytical design of low-cost wearable servo valve using buckled tubes","authors":"Keiichiro Koga, T. Akagi, S. Dohta, A. Nasir","doi":"10.1109/IRIS.2015.7451587","DOIUrl":null,"url":null,"abstract":"Power assisted nursing care systems have received much attentions and those researches have been done actively. In such a control system, an actuator and a control valve are mounted on the human body. Designing the system, the size and weight of the valve become serious concerns. This paper presents a novel, low-cost and wearable servo valve using buckled tube. In the previous study, such a valve was proposed and tested. The analytical model of the valve was also reported. In this paper, the analytical design using the model is carried out. Pressure control performance of the valve is also estimated theoretically with various design parameters As a result, the suitable design parameters can be obtained from the simulation using the model of the valve.","PeriodicalId":175861,"journal":{"name":"2015 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS)","volume":"43 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE International Symposium on Robotics and Intelligent Sensors (IRIS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IRIS.2015.7451587","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Power assisted nursing care systems have received much attentions and those researches have been done actively. In such a control system, an actuator and a control valve are mounted on the human body. Designing the system, the size and weight of the valve become serious concerns. This paper presents a novel, low-cost and wearable servo valve using buckled tube. In the previous study, such a valve was proposed and tested. The analytical model of the valve was also reported. In this paper, the analytical design using the model is carried out. Pressure control performance of the valve is also estimated theoretically with various design parameters As a result, the suitable design parameters can be obtained from the simulation using the model of the valve.
低成本可穿戴扣管伺服阀的解析设计
动力辅助护理系统已受到广泛关注,相关研究也在积极开展。在这种控制系统中,执行器和控制阀安装在人体上。在系统设计中,阀门的尺寸和重量成为人们关注的重点。提出了一种新颖、低成本、可穿戴的扣管伺服阀。在之前的研究中,提出并测试了这种阀门。本文还报道了该阀的解析模型。本文利用该模型进行了分析设计。在不同的设计参数下,对该阀的压力控制性能进行了理论估计,利用该阀的模型进行仿真,得到了合适的设计参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信