Experimental Work on Using Fully Wrapped Post-Tensioned Metal Straps Around Normal Steel Reinforced Beams to Increase Flexural Strength of R.C Beams

Wrya Abdullah, Avesta Omer, S. Rafiq
{"title":"Experimental Work on Using Fully Wrapped Post-Tensioned Metal Straps Around Normal Steel Reinforced Beams to Increase Flexural Strength of R.C Beams","authors":"Wrya Abdullah, Avesta Omer, S. Rafiq","doi":"10.17656/sjes.10147","DOIUrl":null,"url":null,"abstract":"To increase the capacity load carrying of the beams, post tensioned metal straps are fully wrapped around the beams in their tensile zone in this study. In total four normal R.C beams with the depth of 160 mm, height of 240 mm and total length of 2100 mm are cast and tested under four-point load testing. The number of variables is kept to minimum of two which are the number and location of the straps. It is found that using post tensioned metal straps fully wrapped around the beams can increase the load-carrying capacity of the beams by 36% at least and 39% at a max. The main factor in influencing the rate is the location of the straps. A complete guide on using the material along with its application on the beams are explicitly described in the paper.","PeriodicalId":307862,"journal":{"name":"Sulaimani Journal for Engineering Sciences","volume":"9 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sulaimani Journal for Engineering Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17656/sjes.10147","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

To increase the capacity load carrying of the beams, post tensioned metal straps are fully wrapped around the beams in their tensile zone in this study. In total four normal R.C beams with the depth of 160 mm, height of 240 mm and total length of 2100 mm are cast and tested under four-point load testing. The number of variables is kept to minimum of two which are the number and location of the straps. It is found that using post tensioned metal straps fully wrapped around the beams can increase the load-carrying capacity of the beams by 36% at least and 39% at a max. The main factor in influencing the rate is the location of the straps. A complete guide on using the material along with its application on the beams are explicitly described in the paper.
在普通钢筋梁周围采用全包后张金属带提高钢筋混凝土梁抗弯强度的试验研究
为了提高梁的承载能力,本研究在梁的受拉区充分包裹后张拉金属带。共4根普通钢筋混凝土梁,深度160 mm,高度240 mm,总长度2100 mm,浇筑并进行四点荷载试验。变量的数量保持在最小的两个,即绑带的数量和位置。结果表明,采用后张式金属带将梁完全包裹,可使梁的承载能力至少提高36%,最大可提高39%。影响速率的主要因素是带子的位置。一个完整的指南,使用的材料以及它的应用在梁明确地描述在论文中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信