{"title":"A room temperature set-up to compare the quantized Hall resistance with 1 Omega standards","authors":"G. Boella, G. Reedtz","doi":"10.1109/IMTC.1991.161567","DOIUrl":null,"url":null,"abstract":"A method has been developed to relate the mean value of the IEN primary group of 1- Omega standard resistors to the i=2 quantum level of the Hall resistance. It is based on an automated potentiometric system, a 36*360 Omega Hamon network, and a commercial Kusters current comparator bridge. A description of the equipment and of the measurement technique is given together with a detailed uncertainty budget. The typical fractional global uncertainty of the measurement of one standard deviation level is 5*10/sup -8/.<<ETX>>","PeriodicalId":439545,"journal":{"name":"[1991] Conference Record. IEEE Instrumentation and Measurement Technology Conference","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1991-05-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Conference Record. IEEE Instrumentation and Measurement Technology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMTC.1991.161567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

A method has been developed to relate the mean value of the IEN primary group of 1- Omega standard resistors to the i=2 quantum level of the Hall resistance. It is based on an automated potentiometric system, a 36*360 Omega Hamon network, and a commercial Kusters current comparator bridge. A description of the equipment and of the measurement technique is given together with a detailed uncertainty budget. The typical fractional global uncertainty of the measurement of one standard deviation level is 5*10/sup -8/.<>
一个室温设置来比较量子化霍尔电阻与1欧米茄标准
本文提出了一种将1- ω标准电阻的IEN初级组的平均值与霍尔电阻的i=2量子能级相联系的方法。它是基于一个自动电位测量系统,一个36*360欧米茄哈蒙网络,和一个商业库斯特电流比较器桥。对设备和测量技术进行了描述,并给出了详细的不确定度预算。一个标准偏差水平测量的典型分数全局不确定度为5*10/sup -8/。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信