Differences in the standardization of medicinal products based on extracts of chondroitin sulfate

O. Gromova, I. Torshin, B. T. Zaychik, E. V. Shikh, A. O. Ruzhitskiy, A. Galustyan, I. S. Sardaryan, I. Sarvilina
{"title":"Differences in the standardization of medicinal products based on extracts of chondroitin sulfate","authors":"O. Gromova, I. Torshin, B. T. Zaychik, E. V. Shikh, A. O. Ruzhitskiy, A. Galustyan, I. S. Sardaryan, I. Sarvilina","doi":"10.17749/2070-4909/FARMAKOEKONOMIKA.2021.083","DOIUrl":null,"url":null,"abstract":"Objective: a comparative analysis of 6 different chondroprotectors for injection, containing chondroitin sulfate (CS) based on natural extracts.Material and methods. Five samples were studied for each CS extract. The preparations were compared on the basis of profiles of trace element composition, sulfur content, chromatographic analysis and test for total protein. In each sample, the concentration of 72 elements was determined, then averaging was performed and the variances of the content of each element were calculated. To assess the content of the protein fraction, a modified Lowry method with bicincholic acid was used. Chromatographic profiles of the studied CS extracts were measured to estimate the molecular weight distribution.Results. The studied samples differ significantly from each other in the total and individual content of sulfur, toxic and conditionally toxic microelements. According to the analysis of sulfur and trace elements, a cluster of more standardized CS extracts was identified. It was shown that the assessments of the pharmaceutical quality of the studied extracts made by the elemental profile, correspond to the assessments of the quality by the degree of proteins elimination and by the molecular weight characteristics of CS extracts. In particular, the highest total content of toxic elements was found for CS-6 (14.87±1.81 μg/l) and CS-2 (9.20±1.12 μg/l), and the lowest – for CS-4 (1.46±0.23 μg/l), CS-3 (1.92±0.33 μg/l) and CS-1 (2.98±0.25 μg/l). The highest content of protein impurities was also found in CS-6 (9.62 mg/ml) and CS-2 (6.64 mg/ml), and the lowest – in CS-1 (2.87 mg/ml). At the same time, the highest amount of sulfur was found CS-1 (6400 mg/kg) and much less – for CS-2 (370 mg/kg) and CS-6 (100 mg/kg). Significant amounts of the high-molecular fraction of CS (1–40 kDa) were found only in CS-1, and only trace amounts of high-molecular CS forms were present in CS-2 and CS-6.Conclusion. The highest content of cholesterol and sulfur and, at the same time, the lowest content of toxic microelements and proteins were distinguished by the extract obtained from the trachea of a bovine.","PeriodicalId":201824,"journal":{"name":"FARMAKOEKONOMIKA. Modern Pharmacoeconomic and Pharmacoepidemiology","volume":"36 12","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"FARMAKOEKONOMIKA. Modern Pharmacoeconomic and Pharmacoepidemiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17749/2070-4909/FARMAKOEKONOMIKA.2021.083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

Abstract

Objective: a comparative analysis of 6 different chondroprotectors for injection, containing chondroitin sulfate (CS) based on natural extracts.Material and methods. Five samples were studied for each CS extract. The preparations were compared on the basis of profiles of trace element composition, sulfur content, chromatographic analysis and test for total protein. In each sample, the concentration of 72 elements was determined, then averaging was performed and the variances of the content of each element were calculated. To assess the content of the protein fraction, a modified Lowry method with bicincholic acid was used. Chromatographic profiles of the studied CS extracts were measured to estimate the molecular weight distribution.Results. The studied samples differ significantly from each other in the total and individual content of sulfur, toxic and conditionally toxic microelements. According to the analysis of sulfur and trace elements, a cluster of more standardized CS extracts was identified. It was shown that the assessments of the pharmaceutical quality of the studied extracts made by the elemental profile, correspond to the assessments of the quality by the degree of proteins elimination and by the molecular weight characteristics of CS extracts. In particular, the highest total content of toxic elements was found for CS-6 (14.87±1.81 μg/l) and CS-2 (9.20±1.12 μg/l), and the lowest – for CS-4 (1.46±0.23 μg/l), CS-3 (1.92±0.33 μg/l) and CS-1 (2.98±0.25 μg/l). The highest content of protein impurities was also found in CS-6 (9.62 mg/ml) and CS-2 (6.64 mg/ml), and the lowest – in CS-1 (2.87 mg/ml). At the same time, the highest amount of sulfur was found CS-1 (6400 mg/kg) and much less – for CS-2 (370 mg/kg) and CS-6 (100 mg/kg). Significant amounts of the high-molecular fraction of CS (1–40 kDa) were found only in CS-1, and only trace amounts of high-molecular CS forms were present in CS-2 and CS-6.Conclusion. The highest content of cholesterol and sulfur and, at the same time, the lowest content of toxic microelements and proteins were distinguished by the extract obtained from the trachea of a bovine.
基于硫酸软骨素提取物的药品标准化差异
目的:比较分析6种以天然提取物为基础的含硫酸软骨素(CS)的注射用软骨保护剂。材料和方法。每种CS提取物研究了5个样品。通过痕量元素组成、硫含量、色谱分析和总蛋白测定对各制剂进行了比较。测定每个样品中72种元素的浓度,取平均值,计算各元素含量的方差。采用改良的双胆酸Lowry法测定蛋白质组分的含量。测定了所研究的CS提取物的色谱图谱,以估计其分子量分布。所研究的样品在硫、有毒和条件有毒微量元素的总含量和个别含量上存在显著差异。通过对硫和微量元素的分析,鉴定出了一组较为标准化的紫苏提取物。结果表明,用元素谱评价提取物的药用质量,与用蛋白质消除度评价提取物的质量和用CS提取物的分子量特征评价提取物的质量相一致。其中,有毒元素总含量最高的是CS-6(14.87±1.81 μg/l)和CS-2(9.20±1.12 μg/l),最低的是CS-4(1.46±0.23 μg/l)、CS-3(1.92±0.33 μg/l)和CS-1(2.98±0.25 μg/l)。蛋白质杂质含量最高的是CS-6 (9.62 mg/ml)和CS-2 (6.64 mg/ml),最低的是CS-1 (2.87 mg/ml)。同时,硫含量最高的是CS-1 (6400 mg/kg),其次是CS-2 (370 mg/kg)和CS-6 (100 mg/kg)。在CS-1中发现了大量的CS的高分子形式(1-40 kDa),而在CS-2和CS-6中只发现了微量的高分子形式的CS。用牛气管提取液分别鉴定出胆固醇和硫的最高含量和有毒微量元素和蛋白质的最低含量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信