NTS:

{"title":"NTS:","authors":"","doi":"10.2307/j.ctv14rmpqs.13","DOIUrl":null,"url":null,"abstract":"This report summarizes the Spring 1991 2-m Box experiments that were performed at the These studies were sponsored by the Defense Nuclear Agen c y (DNA) under the Radiation Program to obtain mea s ured data for benchmarking the Adjoint Monte Carlo Code System, MASH, Version 1.0. The MASH code system was developed for the Department of Defense and NATO for calculating neutron and gamma - ray radiation fields and shielding protection factors for armored vehicles and military structures against nuclear weapon radiation. In the 2 - m Box experiments, neutron and gamma - ray dose rates and reduction factors were measured in the free - field and as a function of position on an anthropomorphic phantom that was placed outside and inside a borated polyethylene lined steel - walled 2 - m box. The data were acquired at a distance of 400 - m from the APRF reactor. The measurements were performed by APRF, Armed Forces Radiobiology Research Institute (AFRRI), Etablissement Technique Central de l' Armement (ETCA), and Harry Diamond Laboratory (HDL). Calculations were carried out by the Oak Ridge National Laboratory (ORNL) and Science Applications International Corporation (SAI C ). The purpose of these experiments was to measure the neutron and gamma-ray dose rates as a function of detector location on the phantom for cases when the phantom was in the free - field and inside of the box. Neutron measurements were made using a BD - 100R bubble detector and gamma - ray measurements were made using thermoluminescent detectors (TLD). C alculated and measured data were compared in terms of the C / M ratio. DNA mandated that C / M values of ±20% defined acceptable limits for qualifying the MASH code in replicating integral parameters. factors were carried out by and good","PeriodicalId":247283,"journal":{"name":"The Hanford Plaintiffs","volume":"5 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Hanford Plaintiffs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2307/j.ctv14rmpqs.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This report summarizes the Spring 1991 2-m Box experiments that were performed at the These studies were sponsored by the Defense Nuclear Agen c y (DNA) under the Radiation Program to obtain mea s ured data for benchmarking the Adjoint Monte Carlo Code System, MASH, Version 1.0. The MASH code system was developed for the Department of Defense and NATO for calculating neutron and gamma - ray radiation fields and shielding protection factors for armored vehicles and military structures against nuclear weapon radiation. In the 2 - m Box experiments, neutron and gamma - ray dose rates and reduction factors were measured in the free - field and as a function of position on an anthropomorphic phantom that was placed outside and inside a borated polyethylene lined steel - walled 2 - m box. The data were acquired at a distance of 400 - m from the APRF reactor. The measurements were performed by APRF, Armed Forces Radiobiology Research Institute (AFRRI), Etablissement Technique Central de l' Armement (ETCA), and Harry Diamond Laboratory (HDL). Calculations were carried out by the Oak Ridge National Laboratory (ORNL) and Science Applications International Corporation (SAI C ). The purpose of these experiments was to measure the neutron and gamma-ray dose rates as a function of detector location on the phantom for cases when the phantom was in the free - field and inside of the box. Neutron measurements were made using a BD - 100R bubble detector and gamma - ray measurements were made using thermoluminescent detectors (TLD). C alculated and measured data were compared in terms of the C / M ratio. DNA mandated that C / M values of ±20% defined acceptable limits for qualifying the MASH code in replicating integral parameters. factors were carried out by and good
nt:
本报告总结了1991年春季在辐射计划下由国防核机构(DNA)赞助的2米箱实验,以获得伴随蒙特卡罗代码系统(MASH, 1.0版)基准测试的测量数据。MASH代码系统是为国防部和北约开发的,用于计算中子和伽马射线辐射场以及装甲车辆和军事结构对核武器辐射的屏蔽保护系数。在2米箱实验中,中子和伽马射线剂量率和减少因子在自由场和作为位置的函数在拟人体上被测量,拟人体被放置在硼化聚乙烯内衬钢壁2米箱的内外。这些数据是在距离APRF反应堆400米的地方获得的。测量由APRF、武装部队放射生物学研究所(AFRRI)、建立技术中心(ETCA)和Harry Diamond实验室(HDL)进行。计算是由橡树岭国家实验室(ORNL)和国际科学应用公司(SAI C)进行的。这些实验的目的是测量中子和伽马射线剂量率,作为探测器在幽灵上的位置的函数,当幽灵在自由场和盒子内。中子测量采用BD - 100R气泡探测器,伽马射线测量采用热释光探测器(TLD)。用C / M比对C计算数据和实测数据进行比较。DNA规定,C / M值为±20%定义了在复制积分参数时限定MASH代码的可接受限度。各因素均得到了良好的执行
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信