{"title":"Multi-pulse nanosecond electrical breakdown in perfluorinated liquids at 140 kV","authors":"F. Punanov, R. Emlin, P. Morozov, S. Cholakh","doi":"10.1109/PPC.2017.8291194","DOIUrl":null,"url":null,"abstract":"In this work, we present the results of measurements of the electrical breakdown velocity in perfluorinated liquids of several chemical classes. Breakdown is initiated from point anode by 8-ns pulses with a rise time less than 0.5 ns at voltage of 140 kV. We show that perfluorinated esters have close values of breakdown velocity over a wide range of gaps, and demonstrate relatively low jitter in gaps for which time to breakdown is comparable to pulse duration.","PeriodicalId":247019,"journal":{"name":"2017 IEEE 21st International Conference on Pulsed Power (PPC)","volume":"323 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2017 IEEE 21st International Conference on Pulsed Power (PPC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.2017.8291194","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this work, we present the results of measurements of the electrical breakdown velocity in perfluorinated liquids of several chemical classes. Breakdown is initiated from point anode by 8-ns pulses with a rise time less than 0.5 ns at voltage of 140 kV. We show that perfluorinated esters have close values of breakdown velocity over a wide range of gaps, and demonstrate relatively low jitter in gaps for which time to breakdown is comparable to pulse duration.
140千伏全氟液体中的多脉冲纳秒电击穿
在这项工作中,我们提出了几个化学类别的全氟液体的电击穿速度的测量结果。在140 kV电压下,由点阳极产生上升时间小于0.5 ns的8ns脉冲引起击穿。我们表明,全氟化酯具有接近的击穿速度值在大范围的间隙,并证明相对较低的抖动在间隙击穿的时间是相当的脉冲持续时间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信